SECTION  4
ELECTRICAL  CHECK
Procedure:
1.  Turn the power on.
2.  Input the following signal from Signal Generator to FM
 
antenna input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation 
: 75 kHz
Modulation 
: 1 kHz
ANT input 
: 35 dBu (EMF)
Note:  Please use 75 ohm “coaxial cable” to connect SG and the 
 
  set. You cannot use video cable for checking. 
 
  Please use SG whose output impedance is 75 ohm.
3.  Set to FM tuner function and scan the input FM signal with
 automatic 
scanning.
4. Confi rm that input Frequency of A, B and C detected and
 
automatic scanning stops.
The stop of automatic scanning means “The station signal is
received in good condition”.
FM  AUTO  STOP  CHECK
signal
generator
set
+
75 
TUNER  SECTION
0 dB = 1 
ȝV