HCD-SHAKE5, HCD-SHAKE6D (serv.man2) - Sony Audio Service Manual (repair manual). Page 14

Read Sony HCD-SHAKE5 / HCD-SHAKE6D (serv.man2) Service Manual online

HCD-SHAKE5/SHAKE6D
14
[MODEL & DEST WRITE MODE]
This mode is used to set software model & destination.
This mode is only available when no permanent model & 
destination is stored.
Procedure:
1.  Press [OPTIONS] (SHAKE5) / [X] (SHAKE6D) button and 
[FOOTBALL] button simultaneously and hold for 5 seconds.
2.  Fluorescent indicator tube display will show “M XXXXX”.
3. Press 
[+ / 
] (SHAKE5) / [+/PRESET+] (SHAKE6D) / 
[‒ / 
] (SHAKE5) / [‒/PRESET‒] (SHAKE6D) button to 
select the model based on the set’s model.
Product Code
F. Tube display
STORM-JR-CD
“M STORM-JR”
STORM-JR-DVD
“M STORM-JRD”
4.  Press [ENTER] button.
5.  Fluorescent indicator tube display will show “D XXXXX”.
6. Press 
[+ / 
] (SHAKE5) / [+/PRESET+] (SHAKE6D) / 
[‒ / 
] (SHAKE5) / [‒/PRESET‒] (SHAKE6D) button to 
select the destination based on the set’s country.
Area Code Country
F. Tube display
J1
Japan
“D J”
JE1
Tourist
“D JE”
U2/CA2
America, Canada
“D NA”
CEL/CE1/
CE2
Europe (general)
“D CE2”
CEK
U.K.
“D CEK”
RU1/RU3
Russia
“D RU”
AU1
Australia
“D AU”
CN1
China
“D CN”
E12
India, Pakistan, Morocco
“D E12”
E3/E93/
SA2/E15
Middle East, Africa 
(South Africa), Iran
“D E3”
E4
Africa
“D E12”
EA3
Saudi Arabia
“D EA3”
HK1/
HK2/PL1/
SP1/SP2/
SP6/TH1
Hong Kong, Philippines, 
Singapore, Malaysia, 
Thailand
“D ASIA”
KR2
Korea
“D KR”
TW2
Taiwan
“D TW”
E2, E32, 
E51, AR2
Latin America (general), 
Chile, Peru, Argentina
“D LATIN”
BR1
Brazil
“D BR”
MX2, 
MX4
Mexico
“D MX”
7.  Press [ENTER] button to confi rm the selection.
8.  “RESET” appears on the fl uorescent indicator tube. After that, 
the fl uorescent indicator tube becomes blank for a while, and 
the system is reset.
9.  Mode in [PANEL TEST MODE] again to confi rm on the 
model & destination.
[PROTECT KIND CHECK TEST MODE]
This mode is used to check types of protect occurred during 
protector on.
Procedure:
1. During 
protection 
on, 
fl uorescent indicator tube shows blinking
message “PROTECT EXX” where “EXX” represent the error 
code.
2. Press 
[] button and [‒ / 
] (SHAKE5) / [‒/PRESET‒] 
(SHAKE6D) button simultaneously.
3. Fluorescent indicator tube display will toggle between 
“PROTECT” message and protector kind message display.
 
Below table explains on protector kind.
Error 
Code 
Protector 
Message
Description
E01
“AMP OCP”
The over current condition to 
MOSFET occurs by defect of 
MOSFET or defect of PS output 
line.
E03
“POWER 
SUPPLY”
Defect of power supply circuit 
to AMP
E04
“DC DETECT”
DC appears in SP terminal by 
defect of AMP IC and MOS-
FET.
E05
“THERMISTOR”
Unusual heat up of MOSFET by 
improper assembly of heat sink, 
destruction of MOSFET etc.
E06
“FAN BLOCK”
Defect of DC FAN and DC FAN 
driver circuit
To release from this mode:
Press [] button and [‒ / 
] (SHAKE5) / [‒/PRESET‒] 
(SHAKE6D) button simultaneously again or unplug & re-plug in 
the power cord.
If speaker does not have output even if the set status is not in 
PROTECT mode, the following defect might be possible:
Defects
Possible cause
RESET defect
Reset signal status from micom is not ‘H’.
If the PROTECT mode is “POWER SUPPLY”, there is possibility 
of unusual power supply of any of the AMP IC or Pre-amplifi er.
Page of 86
Display

Click on the first or last page to see other HCD-SHAKE5 / HCD-SHAKE6D (serv.man2) service manuals if exist.