– 15 –
3. If errors occur during or after aging, the error messages in the
following table will be displayed.
Table 4-2.
4-4.
FLUORESCENT  INDICATOR  TUBE  AND
CHECK  MODE  FOR  KEYS
4-4-1. Setting the Check Mode
Turn OFF the power of the unit, and set the check mode by press-
ing the following keys together.
  
§ (MD)  +  π (MD)  +  GROOVE
When set, the fluorescent indicator tube and all LEDs will light
up.
4-4-2. Releasing the Check Mode
Press the  POWER  key during the check mode for the fluores-
cent indicator tube, or press any key during the check mode for
each key when the display shows “KEY = OK”. The unit sets into
the mode for normal operations.
4-4-3. Operating the Check Mode
Each time the  ENTER/YES  key is pressed in the check mode for
the fluorescent indicator tube, the display changes in three ways.
The LED lighting pattern can be changed by rotating the MULTI
JOG dial.
Check Mode of Keys
Press the  EDIT/NO  key to set this mode.
When set, the following will be displayed.
MD Section
CD Section
Note 1:
The display counts up each time a key is pressed.
(It will not count up when a key already pressed once is pressed
again.) The order of pressing the key and the count up are not
related.)
When a key is pressed.
When all the keys are pressed,
this will be displayed.
(There are altogether 33 keys.)
When a key is pressed during
this display, this check mode
will end.)
C D1
*
99
1m23 s
track number
disc number
Point at which sound 
jumps occurred.
*
 is displayed at the point the
  sound jump occurred.
  - is displayed normally.
KEY= 0
JOG = 0
K
KEY=
0 JOG = 0
KEY=
1 JOG = 0
KEY=
JOG = 0
O
Error Message
Contents
MD A-Erase
NG Cannot all-erase MD.
MD R-Pause
NG Cannot record-pause MD.
MD D-Input
NG Cannot lock MD digital in.
Cannot playback last MD song.
MD Play
NG (The played back track is not the last
 track (access error)).
MD TOC
NG
MD TOC are abnormal.
(The total track is abnormal.)
MD No Disc
NG
Cannot read MD TOC.
(Disc error)
CD Focus
NG CD focus NG
CD GFS
NG CD GFS (Garde frame sync) NG.
CD TOC
NG 16 seconds after reading CD TOC.
CD SEARCH
NG 16 seconds after CD search.
Not an error message indicating
CD SERVO
OK servo system error. May be displayed
during STOP.
Refer to NOTE 1.
Sound jumps lasting more than 1
second during play back.