CFD-S38L - Sony Audio Service Manual (repair manual). Page 14

Read Sony CFD-S38L Service Manual online

– 14 –
TP (RFO)
– main board (conductor side) –
Adjustment Location:
  CD SECTION
CD section adjustments are done automatically in this set.
In case of operation check, confirm that focus bias.
FOCUS BIAS CHECK
1. Connect the oscilloscope between IC701 pin #£ (TP RFO) and
GND on CD board.
2. Insert the disc (YEDS-18). (Part No. : 3-702-101-01)
3. Press the CD 
fl button.
4. Confirm that the oscilloscope waveform is as shown in the
figure below. (eye pattern)
A good eye pattern means that the diamond shape (     ) in the
center of the waveform can be clearly distinguished.
• RF signal reference waveform (eye pattern)
π
Test Point:
RF level :
1.2 
±
 0.1 Vp-p
VOLT/DIV : 200 mV (10 : 1 probe in use)
TIME/DIV : 500 nS
When observing the eye pattern, set the oscilloscope for AC range
and raise vertical sensitivity.
L3-1
CT3
TP (VT)
(JW17)
TP 
(FM ANT)
MW
TRACKING
ADJUSTMENT
LW
TRACKING
ADJUSTMENT
CT1
L1
FM
TRACKING
ADJUSTMENT
L2
FM
FREQUENCY
COVERAGE
ADJUSTMENT
L4
LW
FREQUENCY
COVERAGE
ADJUSTMENT
L3-2
CT5
– tuner board (component side) –
Page of 42
Display