CFD-S38L - Sony Audio Service Manual (repair manual). Page 13

Read Sony CFD-S38L Service Manual online

– 13 –
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
87.5 MHz
108 MHz
Reading on Digital voltmeter
1.6 ± 0.4 V
4.3 ± 0.1 V
Adjustment Part
<confirmation>
L2
FM TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
CT1
87.5 MHz
108 MHz
MW FREQUENCY COVERAGE
CHECK
Frequency Display
531 kHz
1,611 kHz
Reading on Digital voltmeter
0.8
 + 0.7 V
5.0
 + 1.2 V
      – 0.5 V
       – 0.6 V
Adjustment Part
<confirmation> <confirmation>
MW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-1
CT3
621 kHz
1,404 kHz
LW FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
153 kHz
279 kHz
Reading on Digital voltmeter
0.7
 + 0.3 V
5.3 ± 0.1 V
      – 0.4 V
Adjustment Part
<confirmation>
L4
LW TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L3-2
CT5
162 kHz
261 kHz
Adjustment Location: See page 14.
digital
voltmeter
100 k
TP (VT)
(JW17)
2
 jack (J301)
set
32 
level meter
(range: 0.5–5 V ac)
Put the lead-wire
antenna close to
the set.
AM RF signal
generator
TP (FM ANT)
FM RF signal
generator
0.01 
µ
F
set
  TUNER SECTION     0 dB = 1 µV
• FM Section
Setting:
RADIO (BAND) switch: FM
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• MW/LW Section
Setting:
RADIO (BAND) switch: MW or LW
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM, MW and LW)
• Connecting Digital Voltmeter (FM, MW and LW)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
Page of 42
Display