Read Sony CDP-XB820 Service Manual online
– 15 –
Pin No.
Pin Name
I/O
Function
36
MODEL.SEL2
I
Destination setting terminal (fixed at “L”)
37
AVSS
—
Ground terminal (for A/D converter)
38
RST
I
System reset signal input from the reset signal generator (IC930) “L”: reset
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
For several hundreds msec. after the power supply rises, “L” is input, then it changes to “H”
39
EXTAL
I
Main system clock input terminal (8 MHz)
40
XTAL
O
Main system clock output terminal (8 MHz)
41
VSS
—
Ground terminal
42
TX
O
Sub system clock output terminal Not used (open)
43
TEX
I
Sub system clock input terminal Not used (fixed at “L”)
44
VDD (+5V)
—
Power supply terminal (+5V)
45
VFDP (–30V)
—
Power supply terminal (–30V) (for FL drive)
46
XSEL
O
Not used (open)
47
REINIT
O
Not used (open)
48
RFGF
O
Laser power hold control signal output to the CXA2568M (IC103) “H”: hold on
49 to 66
OPEN
O
Not used (open)
67 to 87
S21 to S1
O
Segment drive signal output to the fluorescent indicator tube (FL801) “H”: goes on
88
1G
O
Grid drive signal output to the fluorescent indicator tube (FL801) “H”: goes on
89
VDD (+5V)
—
Power supply terminal (+5V)
90 to 100
2G to 12G
O
Grid drive signal output to the fluorescent indicator tube (FL801) “H”: goes on
Click on the first or last page to see other CDP-XB820 service manuals if exist.