VC-ME80HM. Service manual front cover to page 56 - Sharp VCR Service Manual (repair manual). Page 14

Read Sharp VC-ME80HM Service Manual online

14
VC-ME80GM
VC-ME80HM
Notes:
1. Hold the torque gauge by hand so that it is not moved.
2. Do not keep the reel disk in lock state. Do not allow long-
time measurement.
CHECKING AND ADJUSTMENT OF TAKE-UP
TORQUE IN RECORD/PLAYBACK MODE
• Remove the cassette housing control assembly.
• After short-circuiting P811 provided at the center
(facing to the main PWB), plug in the power cord.
• Turn off the power switch.
• Open the torque cassette meter lid, and fix it with
tape.
• Load the cassette torque meter into the unit.
• Put the weight (500g) on the torque cassette meter.
• Turn on the power switch.
• Press the REC button, and set LP picture record
mode.
CHECKING AND ADJUSTMENT OF TAKE-UP
TORQUE IN VIDEO SEARCH REWIND MODE
• Remove the cassette housing control assembly.
• After short-circuiting P811 provided at the center
(facing to the main PWB), plug in the power cord.
• Setting
Press the playback button and rewind button to set the
video search rewinding mode.
• Checking
Place the torque gauge on the supply reel disk, and turn it
counterclockwise very slowly (one rotation every 1 to 2
seconds) and check that the torque is within the set value
15.7 
±
 3.5mN
m. (160 
±
 36gf
cm)
Figure 4-11.
Torque gauge
Supply reel disk
Note:
Surely put the torque gauge on the reel disk to measure. If
the torque gauge is raised, accurate measurement is
impossible.
• Adjustment
If the rewinding playback winding-up torque is not within the
setting, replace the limitter pulley assembly.
Note:
The winding-up torque fluctuates due to variation of rota-
tion torque of supply reel disk. Read the center value of
fluctuation as setting.
CCW
Set value LP6.9 
±
 2.5mN
m (70 
±
 25gf
cm)
500g
Torque cassette meter
Figure 4-10.
• Checking
1. Make sure that value is within the setting 6.9
±
2.5mN·m
(70
±
25gf·cm).
2. The winding-up torque fluctuates due to variation of
rotation torque of limitter pulley ass'y. Read the center
value of fluctuation as setting.
3. Set the LP record mode and make sure that the winding-
up torque is within setting.
• Adjustment
If the playback winding-up torque is not within the setting,
replace the limitter pulley assembly.
Note:
When the torque cassette is set, put a weight (500g) to
prevent floating.
When the cassette torque meter is taken out.
Turn off the power switch.
Weight to prevent
float (500g)
Page of 56