13. FUNCTIONS OF AQUOS STANDBY CASE
Method of display
䍃 It is displayed in the top page of the process mode (The page displayed first when entering the process mode: 1/16).
Content of display
1. NORMAL STANDBY CAUSE
䊶 The reason that the set became a power-off by using usually or using the main unit is displayed. 䋨Only the one 㵘
latest) It is not displayed when power supply OFF is carried out with the remote control.
2. ERROR STANDBY CAUSE
䊶 When main CPU becomes a power-off detecting some abnormalities, the reason and the using time of the set by the point
that became a power-off is displayed 5 times.
䊶 In addition, when time information is acquirable from digital broadcasting, the date and time of error generating is recorded
and displayed simultaneously, and when time information cannot be acquired, it becomes the above-mentioned display.
"0" is displayed when abnormalities are not detected once.A display is clearable by operation of the remote control.
* Display will be cleared, if "STANDBY CAUSE RESET" is chosenon page 16/16, "ON" is set up with the above
button (+/-) of the remote control and the "OK." key is pressed.
3. MONITOR ERR STANDBY
If a monitor error is detected because of unusual monitor temperature or the like and the monitor turns off itself,
the error location is pinpointed by the number of blinkings of the power LED and the indicator LED.
The latest four errors detected by the monitor microcomputer are put in memory, and the relevant error code can
be displayed on the MONITOR ERR STANDBY screen.
䃂 Example of display㵘(Top page of process mode: 1/16䋩
1/ 16
[INFO]
BSD
COMP33KHz
JAPAN
46E_UNDER
MAIN Version
1.00 (J 2008/XX/XX/XXX)
BOOT Version
1.04
Monitor Version
1.05
T-CON/H.264 Version
2
CPLD Version
EQ DATA CHECKSUM
ROM
LAMP ERROR
0
MONITOR ERR CAUSE
00 00 00 00
NORMAL STANDBY CAUSE
0
ERROR STANDBY CAUSE
1)0
2)0
3)0
0H 0M
0H 0M
0H 0M
4)0
5)0
0H 0M
0H 0M
* NORMAL STANDBY CAUSE
6
NO_OPERT
No Operation
When based on non-operated OFF
7
NO_SIGNA
No Signal
When based on non-signal OFF
8
PC_MODE1
PC Power Management MODE1 PC: When based on power management MODE1
9
PC_MODE2
PC Power Management MODE2 PC: When based on power management MODE2
0A
SLEEP_TM
Sleep Timer
When based on an off-timer
0C
OFF_232C
Power Off RS232C
When based on a command from RS232C
* ERROR STANDBY CAUSE
5
OUT_OF_R
Out Of Range
Error AVC Temperature
Error Fan Lock
When DVI was used, a wrong signal was input for
eight minutes or more.
13
E_AVCTMP
The tem perature is abnormal.
17
E_FNLOCK
The fan is abnormal.
41
Initialization error of ch0(SCL0) of I2C
42
Initialization error of ch1(SCL1) of I2C
43
Initialization error of ch2(SCL2) of I2C
44
Ch0(SCL0) error of I2C
45
Ch1(SCL1) error of I2C
46
Ch2(SCL2) error of I2C
Description
Display error code
Display character string
Display character string
Display error code
Meaning
Description
Meaning
Page of 10