TU-X1E (serv.man6). Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 4

Read Sharp TU-X1E (serv.man6) Service Manual online

TU-X1E/RU
5 – 4
9/16
[SCART]
1
SCART RGB ADJ
Enter
SCART RGB level adjustment
2
SCART R CUTOFF
65
SCART R CUTOFF adjustment value
3
SCART G CUTOFF
65
SCART G CUTOFF adjustment value
4
SCART B CUTOFF
65
SCART B CUTOFF adjustment value
5
SCART R GAIN
165
SCART R GAIN adjustment value
6
SCART G GAIN
165
SCART G GAIN adjustment value
7
SCART B GAIN
165
SCART B GAIN adjustment value
10/16
[LUMAADJ]
1
VCOM ADJ
0 ERR
Common bias adjustment
2
LCD LUMA ADJ
Enter
Upper and lower brightness difference adjustment
3
LCD LUMA UP
0
4
LCD LUMA DOWN
0
11/16
[FR DDRTEST]
1
DDRA TEST1
Enter
Execute DDRA test 1
2
DDRA TEST2
Enter
Execute DDRA test 2
3
DDRB TEST1
Enter
Execute DDRA test 1
4
DDRB TEST2
Enter
Execute DDRA test 2
5
DDRB TEST3
Enter
Execute DDRA test 3
6
FRC ON/OFF
Enter
Execute FRC ON/OFF
7
SOUSAM DDR BIST
Enter
8
SOUSAS DDR BIST
Enter
12/16
[LEV]
1
R GAIN (Lo)
0
R DRIVE adjustment value
2
G GAIN (L)
0
G DRIVE adjustment value
3
B GAIN (L)
0
B DRIVE adjustment value
4
R GAIN (HI)
0
R DRIVE adjustment value
5
G GAIN (HI)
0
G DRIVE adjustment value
6
B GAIN (HI)
0
B DRIVE adjustment value
13/16
[M EEP SET]
1
MONITOR TIME OUT
ON
Monitor and the main communication time-out setting
2
MONITOR MAX TEMP
47
MONITOR MAX temperature setting
3
MONITOR EEP READ / WRITE
WRITE
MONITOR EEPROM READ/WRITE Setting/execution
4
MONITOR EEP ADR
0x 0
MONITOR EEPROM arbitrary addressing
5
MONITOR EEP DATA
0x 0
MONITOR EEPROM arbitrary data specification
14/16
[M TEST PATTERN]
1
LCD TEST PATTERN
OFF
Pattern with built-in LCD controller display
15/16
[FR REGI]
1
READ/WRITE
READ
Read/Write
2
SLAVE/ADDRESS
SLAVE0
Slave address
3
RESISTER ADDRESS
0x 0
Register address
0x 0
4
WRITE DATA
0x 0
Writing data
0x 0
5
READ DATA
0x 0
Reading data
0x 0
16/16
[ETC]
1
EEP SAVE
OFF
Writing setting values to EEPROM.
2
EEP RECOVER
OFF
Reading setting values from EEPROM.
3
MONITOR ERROR CAUSE RESET
OFF
Reset of monitor error cause
4
STANDBY CAUSE RESET
OFF
Reset stand by cause.
5
MODEL NAME
XS1
Model name setting
6
PANEL SIZE
65
Panel size setting.
7
PRODUCT EEP ADR
0x 0
Don't touch when serving (for producer of factory)
8
PRODUCT EEP DATA
0x 0
Don't touch when serving (for producer of factory)