LC-M3700 (serv.man7). (7) Adjustment procedures - Sharp TV Service Manual (repair manual). Page 4

Read Sharp LC-M3700 (serv.man7) Service Manual online

20
LC-M3700
LC-M3710
3) SECAM signal adjustment
Adjustment item
Adjustment condition
Adjusting method
Signal input
Using a signal generator, feed SECAM split field
color bars (containing 100% white and having color
saturation of 75%) to the video signal input terminal
of INPUT1 or INPUT2.
1
Setting
Set the color system to SECAM.
2
Page4
SECAM Y GAIN
SECAM Y gain
adjustment
Using pin (1) of P802, adjust the gain to
0.70±0.025Vp-p.
3
Page4
SECAM CB GAIN
SECAM color density
adjustment
Using pin (3) of P802, make adjustment so that the
interval indicated in the figure below becomes
0.53±0.025Vp-p.
0.53Vp-p
2) PAL signal adjustment
3
MAIN PAL color
PAL CB GAIN
density adjustment
Using pin (3) of P802, make adjustment so that the
interval indicated in the figure below becomes
0.53±0.025Vp-p.
0.53Vp-p
4
MAIN PAL Cr level adjustment
Using pin (5) of P802, make adjustment so that the
interval indicated in the figure below becomes
0.53±0.025Vp-p.
0.53Vp-p
5
MAIN CONTRAST
CONTRAST 15k
adjustment
Using the IC8805 output (TP8805), adjust the
contrast to 0.90±0.025Vp-p above the pedestal.
TP8805
TP8805
Adjustment item
Adjustment condition
Adjusting method
Page of 13