LC-46LE820E (serv.man10). Adjustment - Sharp TV Service Manual (repair manual). Page 17

Read Sharp LC-46LE820E (serv.man10) Service Manual online

LC-40/46/52LE820E, LC-40/46LU820E
6 – 17
12. White Balance Adjustment
For white balance adjustment, adjust the offset values on pages 11/21.
  [Adjustment procedure]
1) Display the current adjustment status at R/G/B_GAIN (HI). (Page 11/21 of process adjustment)
The signal of 78IRE is input.
2) Read the value of the luminance meter. x = 0.272, y = 0.277
3) Change R_GAIN (HI)/B_GAIN (HI) (Adjustment offset value) on page 11/21 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
(Basically, G is not changed. If adjustment fails with R and B, change G. When G is lowered, the weaker of R or B must be fixed.)
4) Display the adjustment status of the current R/G/B_GAIN (LO).
The signal of 15IRE is input.
Change R_GAIN (LO)/B_GAIN (LO) (adjustment offset value) on page 11/21 of process adjustment so that the values of the luminance meter
approach x = 0.272 and y = 0.277.
5) Both HI and LO are repeating the step from 1 to 4 until becoming an aim value.
[Adjustment reference standard value]
Adjustment spec 
± 0.002                      Inspection spec ± 0.004 (point LO)
Adjustment spec 
± 0.001                      Inspection spec ± 0.002 (point HI)
6) After completing adjustments, set EEP SAVE (21/21) to ON in the process menu to save the white balance adjustment value.
13. Confirmation item
1. HDMI-CEC Inspection
After repairing the CEC function, check the operation about HDMI-CEC circuit
2. CI card Inspection
After repairing the CI function, check that the DTV signal is received in the UK setting by inserting CAM
And check the KEY certification by inserting CAM which is prepare for CI+
3. LAN Inspection
After repairing the LAN function, check the communication by connecting PC and LAN terminal.
[Condition of the unit for inspection] 
: Modulated light (+16), Colour temperature (High)
AV MODE: DYNAMIC
Active Backlight: OFF
OPC: OFF
Asing Time: Min,60 minute
[Input signal condition] 
: HDMI 1080i 15IRE (LO), 78IRE (HI)
[Adjustment reference device] 
: Minolta CA-210
Page of 19
Display

Click on the first or last page to see other LC-46LE820E (serv.man10) service manuals if exist.