LC-46LE820E (serv.man10). Adjustment - Sharp TV Service Manual (repair manual). Page 10

Read Sharp LC-46LE820E (serv.man10) Service Manual online

LC-40/46/52LE820E, LC-40/46LU820E
6 – 10
4. Basic operation in the Public Mode
          Public Mode setting screen.
5. Operation after “RESET”
Select “RESET” in the PUBLIC Mode, and it operates as follows when it is executed (refer to the basic operation).
• The set contents in the PUBLIC mode are initialized.
• It does not exit the PUBLIC mode.
• If “EXCUTE” is not executed, the content that does RESET is not reflected.
6. Setting items (* Item names and selective items are expressed in English.)
1) Power ON fixed [POWER ON FIXED]
If the power button is pressed in the ordinary mode in setting to “FIXED_ALL” and “FIXED_BODYKEY”, the caution is displayed for 5 seconds.
* The OSD display is an example.
If another ODS is previously displayed, the status is reset (MENU or similar).
Vol (+/-) or Cursor ( / )
Change or execution of the set value.
CH (
/
) or Cursor ( / )
Movement to the selected item.
Decision (ok)
Execution (Used by the items “Execution” and “RESET”.)
Public Mode
POWER ON FIXED 
[VARIABLE]
SHUT DOWN MODE 
[NORMAL]
MAXIMUM VOLUME 
[60]
VOLUME FIXED 
[VARIABLE]
VOLUME FIXED LEVEL 
[20]
RC BUTTON 
[RESPOND]
PANEL BUTTON 
[RESPOND]
MENU BUTTON 
[RESPOND]
AV POSITION FIXED 
[VARIABLE]
ON SCREEN DISPLAY 
[YES]
INPUT MODE START 
[NORMAL]
INPUT MODE FIXED 
[VARIABLE]
LOUD SPEAKER 
[ON]
RC PATH THROUGH 
[OFF]
232C POWON 
[DISABLE]
PUBLIC MODE 
[ON]
RESET
EXECUTE
Option 
“VARIABLE”, “FIXED_ALL”, “FIXED_BODYKEY” or “RCRESPOND” (loop enabled)
Default “VARIABLE”
Function 
• VARIABLE
: “POWER/RECEPTION” key on TV unit or remote control is enabled.
• FIXED_ALL“
: “POWER/RECEPTION” key on TV unit or remote control is disabled. 
• FIXED_BODYKEY : only the “MAIN POWER” key on TV unit is disabled (the remote control is enabled).
• RC RESPOND
: the main unit’s POWER switch toggles between ON and Standby (the same operation by 
the remote control).
Key disabled when set 
other than default
• OFF TIMER (SLEEP) (* Only when setting to FIXED_ALL)
Remarks 
• When selecting to “FIXED_ALL”, function related standby factors (see below) doesn't work. and not selecting
   OFF TIMER (Sleep)
   No operation OFF
   No signal OFF (including the power management)
* These items does not exist according to the model.
When power button on the main unit is pressed
       When power button on R/C is pressed
No Power off by power button.
No Power off by remote control.
Page of 19
Display

Click on the first or last page to see other LC-46LE820E (serv.man10) service manuals if exist.