LC-42SA1E (serv.man2). Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 13

Read Sharp LC-42SA1E (serv.man2) Service Manual online

    LC-42SA1E/RU
3 – 13
[6] Special features
* ERROR STANDBY CAUSE (Page 1/11)
The total time when the unit enters the standby due to operational error and cause of error are recorded on EEPROM as much as possible.
The values can be used to locate the fault for repair.
* EEP CLEAR (Page10/11)
Clear of process adjustment EEP value.
8/11
[M GAMMA 1-3]
1
M GAMMA R 1
0
W/B adjustment, gradation 1R adjustment value
2
M GAMMA G 1
0
W/B adjustment, gradation 1G adjustment value
3
M GAMMA B 1
-8
W/B adjustment, gradation 1B adjustment value
4
M GAMMA R 2
0
W/B adjustment, gradation 2R adjustment value
5
M GAMMA G 2
0
W/B adjustment, gradation 2G adjustment value
6
M GAMMA B 2
-11
W/B adjustment, gradation 2B adjustment value
7
M GAMMA R 3
-1
W/B adjustment, gradation 3R adjustment value
8
M GAMMA G 3
0
W/B adjustment, gradation 3G adjustment value
9
M GAMMA B 3
-17
W/B adjustment, gradation 3B adjustment value
10
M GAMMA WRITE
OFF/ON
EEP writing  of  adjustment values
9/11
[M GAMMA 4-6]
1
M GAMMA R 4
0
W/B adjustment, gradation 4R adjustment value
2
M GAMMA G 4
0
W/B adjustment, gradation 4G adjustmnet value
3
M GAMMA B 4
20
W/B adjustment, gradation 4B adjustment value
4
M GAMMA R 5
-9
W/B adjustment, gradation 5R adjustment value
5
M GAMMA G 5
0
W/B adjustment, gradation 5G adjustmnet value
6
M GAMMA B 5
-42
W/B adjustment, gradation 5B adjustment value
7
M GAMMA R 6
-4
W/B adjustment, gradation 6R adjustment value
8
M GAMMA G 6
0
W/B adjustment, gradation 6G adjustment value
9
M GAMMA B 6
41
W/B adjustment, gradation 6B adjustment value
10
M GAMMA WRITE
OFF/ON
EEP writing of adjustment values
10/11
[ETC]
1
EEP CLEAR
OFF/ON
Clear of all adjustment value
2
EEP  CLEAR B
OFF/ON
Clear of setting value of B mode
3
STANDBYCAUSE RESET
OFF/ON
Reset of STANDBY CAUSE
4
AUTO INSTALLATION SW
0/1
1: * * *   0: * * *
5
OPTION
0
6
COUNTRY
AUTO/EURO/UK
Destination setting
7
L ERR RESET
0
LAMP ERR RESET Initialization of L_ERR
8
L ERR STOP
0/1
LAMP ERR Inhibit L_LRR detection
9
I2C-OFF
ENTER
I2C DATA execution
11/11
[LCD]
1
OSC FREQ50
144
INVERTER drive frequency setting
2
OSC FREQ60
144
INVERTER drive frequency setting
3
PWM FREQ50
0
Frequency setting for INVERTER dimmer
4
PWM FREQ60
0
Frequency setting for INVERTER dimmer
5
PWM FREQ
409
Dimmer frequency adjustment
6
PWM DUTY
227
Dimmer DUTY adjustment
7
PWM CTRL
0
Dimmer CONTROL adjustment
Page
 Line
Item
Description
Remarks (adjustment detail, etc.)