LC-42SA1E (serv.man2). Adjustment Procedure - Sharp TV Service Manual (repair manual). Page 12

Read Sharp LC-42SA1E (serv.man2) Service Manual online

LC-42SA1E/RU
3 – 12
[5] Adjustment process mode menu
The character string in brackets [     ] will appear as a page title in the adjustment process menu header.
Page
 Line
Item
Description
Remarks (adjustment detail, etc.)
1/11
[INFO]
1
Main Version
LEW05 01.001(2006/09/15D)1
Main microprocessor version
2
Dev  Version
 1.10
DTV microprocessor version
3
Dev  Loader Version
2.3
DTV microprocessor-Loader version
4
Pic Version
xxxxxx
Pic MICON version
5
TEMP SENSOR
xxxxxx
6
NORMAL STANDBY CAUSE 1 RC_STANDBY
7
ERROR STANDBY CAUSE
[1] 0      00H 00M
Error standby cause Total operating time before error
[2] 0      00H 00M
[3] 0      00H 00M
[4] 0      00H 00M
[5] 0      00H 00M
2/11
[INIT]
1
Factory Init
 [EURO/UK/ITALY/FRANCE/RUS-
SIA]ENTER
Initialization to factory settings execution
2
Inch Setting
26/32/37/42
Inch present setting
3
Public Mode
OFF/ON
HOTEL MODE flag setting
4
Center Acutime
xxH xxM
Main operating hours
5
RESET
OFF/ON
Main operating hours reset
6
Backlight Acutime
xxH xxM
Backlight operating hours
7
RESET
OFF/ON
Backlight operating hours reset
8
Picture Read Pos X
0-xxx
x-axis setting of picture data
9
Picture Read Pos Y
0-xxx
y-axis setting of picture data
10
Picture Read
ON/OFF
Start/stop of picture data
3/11
[PAL.SECAM. N358]
1
RF-AGC ADJ
ENTER
RF-AGC auto adjustment execution
2
PAL+TUNER ADJ
ENTER
PAL TUNER auto adjustment execution
3
PAL ADJ
ENTER
PAL auto adjustment execution
4
TUNER ADJ
ENTER
TUNER auto adjustment execution
5
CONTRAST SD
32
PAL contrast adjustment
6
SECAM CB OFFSET
1
SECAM offset adjustment
7
SECAM CR OFFSET
1
SECAM offset adjustment
8
TUNER A DAC
32
TUNER DAC  adjustment
9
RF AGC
20
RF AGC adjustment
4/11
[COMP 15K]
1
COMP 15K ADJ
ENTER
COMP15K auto adjustment execution
2
COMP 15K CONTRAST
32
Contrast adjustment
5/11
[HDTV]
1
HDTV CONTRAST
32
HDTV Contrast adjustment
6/11
[SMPTE]
1
RF-AGC ADJ
ENTER
RF-AGC auto adjustment execution
2
PAL+TUNER ADJ
ENTER
PAL TUNER auto adjustment execution
3
PAL ADJ
ENTER
PAL auto adjustment execution
4
TUNER ADJ
ENTER
TUNER auto adjustment execution
5
CONTRAST SD
31
PAL contrast adjustment
6
SECAM CB OFFSET
1
SECAM offset adjustment
7
SECAM CR OFFSET
1
SECAM offset adjustment
8
TUNER A DAC
35
TUNER DAC  adjustment
9
RF AGC
24
RF AGC adjustment
7/11
[M GAMMA INFO]
1
M GAMMA IN 1
160
W/B adjustment, gradation 1 input setting
2
M GAMMA IN 2
320
W/B adjustment, gradation 2 input setting
3
M GAMMA IN 3
480
W/B adjustment, gradation 3 input setting
4
M GAMMA IN 4
640
W/B adjustment, gradation 4 input setting
5
M GAMMA IN 5
800
W/B adjustment, gradation 5 input setting
6
M GAMMA IN 6
960
W/B adjustment, gradation 6 input setting
7
M GAMMA WRITE
OFF/ON
EEP writing  of  adjustment values
8
M GAMMA RESET
OFF/ON
Initialization of  adjustment values
Page of 18
Display

Click on the first or last page to see other LC-42SA1E (serv.man2) service manuals if exist.