37VT-26H. Serivce manual page 1 to page 62 - Sharp TV Service Manual (repair manual). Page 61

Read Sharp 37VT-26H Service Manual online

61
37VT-26H(GY)
FLOWCHART NO. 2-6
NO VERTICAL SCAN
NO
NO
NO
YES
Vertical freq check
FLOWCHART NO. 2-7
NO SOUND
Does waveform appear 
at pin (8) of IC301 ?
YES
Does waveform appear 
at pin (3) of IC351 ?
Check IC301, TU Circuit 
and adjacent parts.
Check IC351 and 
adjacent parts.
Check pin (29) of IC801  
and adjacent parts.
NO
YES
FLOWCHART NO. 2-8
NO PLAYBACK PICTURE
Is there a signal at pin (1) 
of IC801 ?
Check IC801 and 
adjacent parts as same 
as "NO PICTURE".
Check the VCR:
TROUBLE SHOOTING 
"NO PLAYBACK".
YES
Does waveform appear 
at pin (8) of IC351 ?
Check the speaker.
Normal
Pin (53) of IC801
Abnormal
IC801 pin (54) bias 
check.
Normal
IC801
Abnormal
IC501 bias check.
Normal
D501, D504, C502, C504, 
C511, R513
Abnormal
Check IC501, the 
connectors F5, F6 and  
adjacent parts.
NO
YES
FLOWCHART NO. 2-9
NO PLAYBACK SOUND
Is there a signal at pin (28) 
of IC801 ?
Check the TV: 
TROUBLE SHOOTING 
"NO SOUND".
Check the VCR:
TROUBLE SHOOTING 
"NO SOUND".