FLOWCHART NO. 1-11
DRUM SERVO TROUBLESHOOTING
Drum servo does not function.
Is there 16MHz 
oscillation at pins (38) 
and (39) of IC2001 ?
Is there the durm PG 
signal at pin (90) of 
IC2001 ?
Is there the reference 
signal (V-sync.) at pin 
(56) of IC2001 ?
Is there the head 
switching pulse at pin 
(18) of IC2001 ?
In REC mode
In PB mode
Is there the drum control 
output at pin (77) of 
IC2001 ?
Is there the durm FG 
signal at pin (89) of 
IC2001 ?
Check FG and PG signal 
at pins (3) and (5) of the 
connector ME and the 
drum motor.
Check the signal line of 
drum PG.
Is there the drum control 
voltage applied to pin (7) 
of connector AD ?
Check the composite 
sync. signal at pin (14) of 
IC2201, Q2217, Q2218 
and Q7706 all the way up 
to pin (56) of IC2001.
Check the signal line 
between pin (7) of AD 
and pin (77) of IC2001.
Check and replace the 
drum motor.
See FLOWCHART NO. 
1-8.
NO
NO
NO
NO
NO
NO
NO
Replace IC2001.
Check X7701, C7706 
and C7707.
Replace IC2001.
Is pin (78) of IC2001 in 
high impedance ?