37VT-26H. Serivce manual page 1 to page 62 - Sharp TV Service Manual (repair manual). Page 53

Read Sharp 37VT-26H Service Manual online

53
37VT-26H(GY)
NO
YES
YES
YES
NO
FLOWCHART NO. 1-9
DRUM MOTOR TROUBLESHOOTING
The drum motor fails to run.
Is the voltage more than about 2.6V 
applied at pin (7) of connector AD ?
Check the STAND-BY5V line.
Is 5V at pin (1) of connector AD ?
NO
Check the PC12V line.
Is 12V at pin (4) of connector AD ?
Check the connection between 
connectors AD and ME or 
check/replace the drum motor.
Check between the connector AD 
and pin (77) of IC2001, and between 
the connector AD and pin (78) of  
IC2001.
NO
YES
YES
YES
NO
FLOWCHART NO. 1-10
The drum motor runs only for a few seconds.
Is drum PG signal at pin (3) of AD 
connector ?
Check between the connector AD and 
all the way up to pin (90) of IC2001.
Is drum PG signal at pin (90) of 
IC2001 ?
NO
Check/replace IC2001.
Is H. SW. pulse at pin (18) of 
IC2001 ?
Check the connection between 
connector AD and ME or 
check/replace the drum motor.
Check the drum motor.
Page of 62