XG-V10WE. Version 1.1 - Sharp Projector Handy Guide. Page 55

Read Sharp XG-V10WE Handy Guide online

Adjustment of the Mirrors
Version 1.1
Issue 04/2006
55
SHARP ELECTRONICS (UK) LTD
PROJECTOR TECHNICAL SUPPORT
TECHNICAL SERVICES GROUP
1. Adjusting the mirror optical axis
The optical axis must be readjusted to correct possible eclipse that occurs with the R,
G or B LCD panel.
This readjustment is usually required when an optical part in the optical mechanism
has been replaced, and may be needed when a LCD panel has been replaced.
1. Disconnect the LCD flat cable.
2. Get the lamp on. Be sure to start the cooling fan too.
(Eclipse with the R LCD panel: Screen edges appearing in cyan)
3. Loosen the lock screws of the M5 adjusting lever.
4. Watching the image on the screen, turn or slide the M5 adjusting lever until the eclipse
disappears from the screen. Now tighten up the lock screws.
(Eclipse with the G LCD panel: Screen edges appearing in magenta)
3. Loosen the lock screws of the M3 adjusting lever.
4. Watching the image on the screen, turn or slide the M3 adjusting lever until the eclipse
disappears from the screen. Now tighten up the lock screws.
(Eclipse with the B LCD panel: Screen edges appearing in yellow)
3. Loosen the lock screws of the M6 adjusting lever.
4. Watching the image on the screen, turn or slide the M6 adjusting lever until the eclipse
disappears from the screen. Now tighten up the lock screws.
2. Adjusting the orientation of polarizer
The contrast must be optimised when the polarizer or an optical mechanism part has
been replaced.
1. Turn on the power.
2. If the background is blue, clear the screen and get it black.
3. Loosen the two lock screws of the polarizer (two for each plate).
4. Press the heads of the lock screws in the arrow directions until the onscreen contrast
becomes best. Finally tighten up the lock screws.
3. Adjusting the PBS
This adjustment may be required when the optical mechanism has been disassembled.
Colours uneven on the right and left halves-onscreen can be corrected here. Usually
there is no need to make this adjustment.
It is enough to have the lamp-adjusting groove in alignment.
1. Turn on the power.
2. Loosen the PBS lock screw.
3. Feed a white-only signal, or call the process mode and get the screen white only.
4. Put the eccentric screwdriver (9EQDRiVER-NV1A) in the PBS adjusting groove.
5. Watching the image on the screen, turn the eccentric screwdriver until the right-and-left
colours onscreen become most even. Finally tighten up the lock screw.
4. Adjusting the lamp optical axis
The lamp optical axis is optimised to obtain the best colour evenness and brightness.
Usually there is no need to make this adjustment because the replacement lamp unit
(BQC-XGV10WU/1) has been delivered factory-adjusted.
1. Turn on the power.
2. Loosen the three lamp lock screws.
3. Feed a white-only signal, or call the process mode and get the screen white only.
4. Put the eccentric screwdriver (9EQDRiVER-NV1A) in the lamp-adjusting groove.
5. Watching the image on the screen, turn the eccentric screwdriver until the right-and-left
colours onscreen become most even. Finally tighten up the lock screws.