Sharp Electronics (UK) Limited
Reference LV-037
Revision  1
White – Carry out as required, Yellow – Carry out as required and whenever the unit comes in for service, Red – Carry out on all units
LCP990301
Month of Issue: March 1999
        Classification:              White
LCP TECHNICAL BULLETIN
Page 1 of 1
MODELS
XGXV1E
XGXV2E
SYMPTOM No operation.
CAUSE
Failure of C714 - short circuit.
ACTION
Replace C714 with the component listed below.
Note that the components below may also be damaged when C714 fails.
R715, R726, R727, R760, R1734, IC101, Q1708, etc....
Replace defective components as necessary.
REF NO
DESCRIPTION
PART NUMBER
PRICE CODE
C714
Capacitor 2200pF, 2kV
95KUGZ1171ZZ
AE
Display

Download Sharp XG-NV1E (serv.man25) Technical Bulletin

Here you can read online and download Sharp XG-NV1E (serv.man25) Technical Bulletin in PDF. XG-NV1E (serv.man25) technical bulletin will guide through the process and help you recover, restore, fix, disassemble and repair Sharp XG-NV1E (serv.man25) Projector. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.