XG-NV1E (serv.man18). Technical manual - Sharp Projector Service Manual (repair manual). Page 56

Read Sharp XG-NV1E (serv.man18) Service Manual online

XG-NV1U
56
DECIMAL
DELAY TIME
MULTIPLIER
(STEP SIZE = 2/LLC)
CONTROL BITS
HSYS7 HSYS6 HSYS5 HSYS4 HSYS3 HSYS2 HSYS1 HSYS0
8-7-3. Subaddress 02 (DATA BYTE 023 to 016)
Horizontal synchronization stop 50 Hz (HSYS)
+191
-382
1
0
1
1
1
1
1
1
-64
+128
1
1
0
0
0
0
0
0
DECIMAL
DELAY TIME
MULTIPLIER
(STEP SIZE = 2/LLC)
CONTROL BITS
HCLB7 HCLB6 HCLB5 HCLB4 HCLB3 HCLB2 HCLB1 HCLB0
8-7-4. Subaddress 03 (DATA BYTE 031 to 024)
Horizontal clamping begin 50 Hz (HCLB)
+127
-254
0
1
1
1
1
1
1
1
-128
+256
1
0
0
0
0
0
0
0
DECIMAL
DELAY TIME
MULTIPLIER
(STEP SIZE = 2/LLC)
CONTROL BITS
HCLS7 HCLS6 HCLS5 HCLS4 HCLS3 HCLS2 HCLS1 HCLS0
8-7-5. Subaddress 04 (DATA BYTE 039 to 032)
Horizontal clamping stop 50 Hz (HCLS)
+127
-254
0
1
1
1
1
1
1
1
-128
+256
1
0
0
0
0
0
0
0
8-7-6. Subaddress 05 (DATA BYTE 047 to 040)
Horizontal synchronization start after PHI1 50 Hz (HPHI)
DECIMAL
DELAY TIME
MULTIPLIER
(STEP SIZE = 4/LLC)
CONTROL BITS
HPHI7
HPHI6
HPHI5
HPHI4
HPHI3
HPHI2
HPHI1
HPHI0
+127
0
1
1
1
1
1
1
1
+118
0
1
1
1
0
1
1
0
+117
0
1
1
1
0
1
0
1
-118
1
0
0
0
1
0
1
0
-119
1
0
0
0
1
0
0
1
-128
1
0
0
0
0
0
0
0
forbidden;
outside available central
counter range
-32µs
(max. negative value)
+31.7µs
(max. positive value)
forbidden;
outside available central
counter range
Page of 76
Display