Read Sharp XG-MB67X (serv.man11) Service Manual online
XG-MB67X
6 – 2
If shading shown in Figure 1 appears on the screen after replacing DMD, turn the adjustment screw of the optical engine to adjust the lighting area of
DMD.
DMD.
1. Loosen the adjustment lever fixing screw
. After adjusting the lighting area with the adjustment lever
, tighten the adjustment lever fixing
screw .
When mounting DMD, tighten the 4 screws evenly.
1
2
1
Fig. 1
Shading
Tightening order: 1
2
3
4
Screw torque: 0.44 ± 0.05 N·m