Read Sharp XG-C455W (serv.man5) Service Manual online
XG-C455W/PG-C355W
5 – 7
Checking the LAN
LAN communication is disabled even though
connecting the control PC with a LAN cable. The
LINK LED (green) does not light up.
connecting the control PC with a LAN cable. The
LINK LED (green) does not light up.
Are the connection of connecting cable and the
settings of IP address, sub-net address and
default gateway correct?
settings of IP address, sub-net address and
default gateway correct?
NO
Check the connecting cable and LAN settings. If the LAN settings are
unknown, contact the network administrator.
If the network settings cannot be saved, replace IC6708 (EEP ROM) as it may
be defective.
unknown, contact the network administrator.
If the network settings cannot be saved, replace IC6708 (EEP ROM) as it may
be defective.
YES
Note: When IC6708 (EEP ROM) is replaced, the MAC address returns to
default. Refer to "Resetting after replacing IC6708 (EEP ROM)" to reset.
default. Refer to "Resetting after replacing IC6708 (EEP ROM)" to reset.
Are the network device (e.g. Hub) between the
control PC and XG-C455W and cable normal?
control PC and XG-C455W and cable normal?
NO
Repair defective parts in the network.
YES
When data is sent from the control PC, do pins
(30) and (31) of IC8201 (PHY receiver) receive
signals?
(30) and (31) of IC8201 (PHY receiver) receive
signals?
NO
Check the peripheral circuit of J8201 (RJ-45 jack with built-in transformer).
YES
Check the PHY receiver IC8201 and the periph-
eral circuits of the microprocessor IC8001.
eral circuits of the microprocessor IC8001.