XG-C455W (serv.man5). Troubleshooting Table - Sharp Projector Service Manual (repair manual). Page 3

Read Sharp XG-C455W (serv.man5) Service Manual online

XG-C455W/PG-C355W
5 – 3
Lamp fails to light-up
Turn on the power switch. 
Is discharging sound heard 
from lamp?
YES
Is the lamp out of 
socket?
YES
Reconnect the lamp into 
socket.
NO
NO
Replace the lamp.
Is the ballast cooling fan running?
YES
Check the cooling fan cir-
cuits.
NO
Does the power LED 
flash red in 0.5 second 
interval?
YES
Check the “RCS” signal. 
(Air filter cover/Lamp door/
Lens door)
NO
Is the DC voltage of 380V applied to pin(1) of P702 connector?
NO
Check the power supply cir-
cuits.
YES
Is LOW LEVEL voltage 
applied between pins(3) 
and (4) of Main's P1702 
connector?
NO
Is the P1702 connector 
disconnect?
NO
The lamp light-up. After 
about 30 seconds, the 
TEMP LED flash red and 
the lamp turn off.
YES
Check the TEMP1, 
TEMP2 and TEMP0 
signal line.
YES
YES
NO
Replace the ballast.
Reconnect it into 
socket correctly.
Check the microprocessor 
and its peripheral circuits.