14
PG-M25X
3. Removing the operation PWB
3-1. Remove the two lock screws from the operation PWB and slightly raise this PWB.
3-2. Disconnect the connectors.
4. Removing the optical mechanism
4-1. Remove the two lock screws from the lamp socket.
4-2. Raise the two lamp socket lead fixtures.
4-3. Disconnect the connectors.
4-4. Remove the six lock screws from the optical mechanism.
3-2
3-1
3-1
Operation PWB unit
4-4
4-3
4-1
Optical mechanism
4-2