PG-B10S (serv.man35). (part 4) Corrections, screen setup, appendix - Sharp Projector User Guide / Operation Manual. Page 12

Read Sharp PG-B10S (serv.man35) User Guide / Operation Manual online

-61
Appendix
1
2
Replacing the Air Filter
Tab
• This projector is equipped with air fil-
ters to ensure the optimal operating
condition of the projector.
• The air filters should be cleaned every
100 hours of use. Clean the filters more
often when the projector is used in a
dusty or smoky location.
• Ask your nearest Sharp Authorized Pro-
jector Dealer or Service Center to ex-
change the filter (PFILDA010WJZZ)
when it is no longer possible to clean.
Cleaning and Replacing
the Air Filter
1
Press 
 on the projector
or 
STANDBY
 on the remote control to
put the projector into the
standby mode.
Wait until the cooling fan stops.
2
Disconnect the power cord.
Unplug the power cord from the AC
socket.
3
Remove the filter cover.
Turn the projector over. Loosen the user
service screw (1) that secures the fil-
ter cover. Pressing the tab, remove the
filter cover (2).
STANDBY button
Air filter (not removable)
User service screw
Air filter (removable)
"
"
"
"
"
 Bottom view
"
"
"
"
"
 Front view
STANDBY
button
STANDBY
AC socket
Page of 29