MX-M1100 MAINTENANCE 9 – 7
5. Photoconductor section
A. Maintenance table
✕: Check (Clean, replace, or adjust as necessary.) {: Clean ▲: Replace U: Adjust ✩: Lubricate : Shift the position
No.
Part name
When
calling
500
K
1000
K
1500
K
2000
K
2500
K
3000
K
Remark
[Refer to the Parts Guide. Block/Item No.]
(Only the replacement parts are described.)
1
OPC drum
✕
✕
▲
✕
▲
✕
▲
2
Cleaning blade
✕
▲
▲
▲
▲
▲
▲
[PG No.: [36] - 35]
When replacing, apply stearic acid. (UKOG-0312FCZZ)
When replacing, apply stearic acid. (UKOG-0312FCZZ)
3
Sub blade
✕
▲
▲
▲
▲
▲
▲
[PG No.: [36] - 54]
4
Side seal F, R
✕
▲
▲
▲
▲
▲
▲
[PG No.: [36] - 20, [36] - 66]
5
Drum separation pawl
✕
▲
▲
▲
▲
▲
▲
When replacing, shift the separation pawl mounting
position.
[PG No.: [37] - 2]
position.
[PG No.: [37] - 2]
6
Discharge lamp
✕
{
{
{
{
{
{
7
Procon sensor
✕
{
{
{
{
{
{
8
Surface potential sensor
✕
{
{
{
{
{
{
Hold the sensor so that no foreign material enters the
port of the sensor. Wipe it with waste cloth. Use alcohol if
it is dirtied with oil.
port of the sensor. Wipe it with waste cloth. Use alcohol if
it is dirtied with oil.
9
Cleaning brush roller
✕
{
{
{
{
{
▲
[PG No.: [36] - 61]
10
Charger wire
{
▲
▲
▲
▲
▲
▲
[PG No.: [38] - 25]
11
Screen grid
✕
▲
▲
▲
▲
▲
▲
[PG No.: [38] - 26]
12
Charger cleaner
▲
▲
▲
▲
▲
▲
[PG No.: [38] - 6]
13
Charger cushion
▲
▲
▲
▲
▲
▲
[PG No.: [38] - 6]
14
Duct sheet
▲
▲
▲
▲
▲
▲
[PG No.: [74] - 61]
15
Blade side seal F, R
✕
✕
✕
✕
✕
✕
▲
[PG No.: [36] - 24, [36] - 58]
16
Cleaning brush bearing
✕
17
Cleaning brush drive bearing
✕
18
Separation pawl oscillation bearing
✕
19
Auxiliary cleaning brush bearing
✕
20
Bearing
✕
21
Separation pawl oscillation arm
✕
22
Separation pawl oscillation shaft
✕
23
Ball bearings
✕
24
Gears
✕
25
Cleaner base guide
▲
▲
▲
▲
▲
▲
[PG No.: [38] - 3]
26
Sub blade seal F, R
✕
✕
✕
✕
✕
✕
27
Main charger case
{
{
{
{
{
▲
[PG No.: [38] - 9]
1
5
5
5
5
6
8
19
9
16
20
11
27
2
15
15
21
19
17
24
23
4
26
10
13
7
3
18
22
12
25
13
26
4
14