Read Sharp MX-M950 / MX-MM1100 (serv.man39) Service Manual online
MX-M1100 SELF DIAG AND TROUBLE CODE 8 – 13
F1-00
Machine detection after-process
system communication trouble
system communication trouble
F1-01
Jogger motor trouble
F1-02
Upper transport motor trouble
F1-03
Lower transport motor trouble
F1-06
Shift paper exit motor trouble
F1-07
Tray shift motor trouble
F1-08
Stapler front / rear motor trouble
(finisher + saddle unit + inserter)
Staple shift motor trouble
(saddle finisher)
(finisher + saddle unit + inserter)
Staple shift motor trouble
(saddle finisher)
F1-09
Staple diagonal motor trouble
(finisher + saddle unit + inserter)
Staple diagonal motor trouble
(saddle finisher)
(finisher + saddle unit + inserter)
Staple diagonal motor trouble
(saddle finisher)
F1-10
Staple motor trouble
(finisher + saddle unit + inserter)
Staple motor 1 (edge binding)
(saddle finisher)
(finisher + saddle unit + inserter)
Staple motor 1 (edge binding)
(saddle finisher)
Detail
Communication line test error when turning ON the
power or after canceling the exclusive simulation.
Communication error with the finisher.
power or after canceling the exclusive simulation.
Communication error with the finisher.
Section
PCU
Cause
Contact failure or disconnection of the connector and
harness between the PCU and the finisher.
Finisher control PWB trouble.
Control PWB (PCU) trouble.
Malfunction due to noises.
harness between the PCU and the finisher.
Finisher control PWB trouble.
Control PWB (PCU) trouble.
Malfunction due to noises.
Check &
Remedy
Remedy
Canceled by turning OFF/ON the power.
Check the connector and the harness of the
communication line.
Replace the finisher control PWB, or replace the PCU
PWB.
Check the connector and the harness of the
communication line.
Replace the finisher control PWB, or replace the PCU
PWB.
Detail
Jogger shift motor abnormality in the finisher staple
compiler
compiler
Section
PCU
Cause
Motor lock, control PWB trouble, home position sensor
breakdown, connection harness / connector connection
trouble.
breakdown, connection harness / connector connection
trouble.
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the jogger motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Detail
Finisher upper side transport section motor abnormality
Section
PCU
Cause
Motor lock, control PWB trouble, encoder breakdown,
connection harness/connector connection trouble.
connection harness/connector connection trouble.
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the upper
transport motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
transport motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Detail
Finisher lower side transport section motor abnormality
Section
PCU
Cause
Motor lock, control PWB trouble, encoder breakdown,
connection harness/connector connection trouble.
connection harness/connector connection trouble.
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the lower
transport motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
transport motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Detail
Finisher shift paper exit section motor abnormality
Section
PCU
Cause
Motor harness short/open, control PWB trouble,
connection harness/connector trouble.
connection harness/connector trouble.
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the shift paper
exit motor.
Check connection from the control PWB to the motor.
Replace the control PWB.
exit motor.
Check connection from the control PWB to the motor.
Replace the control PWB.
Detail
Finisher offset tray shift motor abnormality
Section
PCU
Cause
Motor lock, control PWB trouble,
home position sensor breakdown,
connection harness/connector connection trouble
home position sensor breakdown,
connection harness/connector connection trouble
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the tray shift
motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Detail
Finisher staple unit shift motor abnormality
Section
PCU
Cause
Motor lock, control PWB trouble,
home position sensor breakdown,
connection harness/connector connection trouble.
home position sensor breakdown,
connection harness/connector connection trouble.
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the staple back/
forward shift motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
forward shift motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Detail
Finisher stapler unit diagonal shift motor abnormality
Section
PCU
Cause
Motor lock, control PWB trouble,
home position sensor breakdown,
connection harness/connector connection trouble.
home position sensor breakdown,
connection harness/connector connection trouble.
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the stapler
diagonal motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
diagonal motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Detail
Finisher staple motor abnormality
Section
PCU
Cause
Motor lock, control PWB trouble,
home position sensor breakdown,
connection harness/connector connection trouble.
home position sensor breakdown,
connection harness/connector connection trouble.
Check &
Remedy
Remedy
Use Sim. 3-3 to check the operation of the staple motor.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.
Check connection from the control PWB to the motor.
Replace the control PWB and the sensor part.