MX-M1100 SELF DIAG AND TROUBLE CODE  8 – 12
 
E7-62
Controller connection  trouble
(scanner)
 
E7-63
Controller connection trouble 
(Operation)
 
E7-65
PWB information sum error 
(controller detection)
 
E7-70
Scanner connection trouble
 
E7-71
 DSPF connection trouble
 
E7-75
PWB information sum error 
(scanner detection)
 
E7-80
Communication trouble between the 
ICU and the scanner (ICU detection)
 
E7-90
Communication trouble between the 
ICU and the PCU. (ICU detection)
 
EE-EL
Auto development adjustment trouble
(Overtone abnormality)  
<Detected only when Sim. 25-2,  
no trouble memory, only display>
 
EE-EU
Auto development adjustment trouble
(Undertone abnormality) 
<Detected only when Sim. 25-2,  
no trouble memory, only display)
Detail
Controller connection trouble.
Compatibility trouble between the controller and the 
scanner.
Section
ICU
Cause
Combination error between the controller PWB and the 
engine.
Check & 
Remedy
Check combination between the controller PWB and the 
scanner. 
Detail
Controller connection trouble.
Compatible trouble between the controller and the 
operation.
Section
ICU
Cause
Combination error between the controller PWB and the 
operation.
Check & 
Remedy
Check the controller PWB.
Check combination between the controller PWB and the 
operation.
Detail
EEPROM PWB information sum error
Section
ICU
Cause
EEPROM device trouble.
EEPROM device contact trouble.
Device access error due to noises.
Check & 
Remedy
Replace the PWB.
Detail
Unknown PWB identification information is detected on 
the SCU PWB
Section
SCU
Cause
The PWB / firmware which is not supported by the 
machine specifications is connected. 
Check & 
Remedy
Check the firmware kind and the version.
Check the SCU PWB.
Detail
An unknown PWB identification information is detected 
in the DSPF PWB/ combination abnormality with the 
SCU PWB
Section
SCU
Cause
PWB / firmware which does not support the machine 
specifications is connected. 
Check & 
Remedy
Firmware kind / Version check.
DSPF PWB trouble.
Detail
EEPROM PWB information sum error
Section
SCU
Cause
EEPROM device trouble.
EEPROM device contact trouble.
Device access error due to noises.
Check & 
Remedy
Replace the SCU PWB.
Detail
Communication establishment error, framing error, 
parity error, protocol error
Section
ICU
Cause
Slave unit PWB connector connection trouble.
Slave unit PWB and ICU PWB harness trouble.
Slave unit PWB mother board connector pin breakage.
Check & 
Remedy
Check connection of the connector and the harness 
between the slave unit PWB and the ICU PWB. 
Check grounding of the machine. 
Detail
Communication establishment error, framing error, 
parity error, protocol error
Section
ICU
Cause
Slave unit PWB connector connection trouble.
Slave unit PWB and ICU PWB harness trouble.
Slave unit PWB mother board connector pin breakage.
Check & 
Remedy
Check connection of the connector and the harness 
between the slave unit PWB and the ICU PWB. 
Check grounding of the machine. 
Detail
The sample level is 76 or less or the control voltage is 
208 or above
Section
PCU
Cause
Toner density sensor trouble, charging voltage /
developing voltage trouble, toner density trouble, 
developing unit trouble, PCU PWB trouble.
Check & 
Remedy
Execute the auto development adjustment with 
Sim. 25-2. 
Detail
The sample level is 178 or above or the control voltage 
is 51 or less
Section
PCU
Cause
Toner density sensor trouble, charging voltage /
developing voltage trouble, toner density trouble, 
developing unit trouble, PCU PWB trouble.
Check & 
Remedy
Execute the auto development adjustment with 
Sim. 25-2. 