Read Sharp MX-M950 / MX-MM1100 (serv.man39) Service Manual online
MX-M1100 SELF DIAG AND TROUBLE CODE 8 – 7
FF
00
Double feed detection trouble (PCU)
PCU
●
10
Double feed detection trouble (SCU)
SCU
●
H2
00
Non-contact main thermistor (detection) open
(RTH1-d_D)
(RTH1-d_D)
PCU
●
01
Sub thermistor open (RTH2)
PCU
●
02
Lower thermistor open (PRTH)
PCU
●
03
Non-contact main thermistor (reparation) open
(RTH1-d_C)
(RTH1-d_C)
PCU
●
H3
00
Non-contact main thermistor high temperature
trouble (RTH1_d)
trouble (RTH1_d)
PCU
●
01
Sub thermistor high temperature trouble (RTH2)
PCU
●
02
Lower thermistor high temperature trouble (PRTH)
PCU
●
H4
00
Non-contact main thermistor low temperature
trouble (RTH1-d)
trouble (RTH1-d)
PCU
●
01
Sub thermistor low temperature trouble (RTH2)
PCU
●
02
Lower thermistor low temperature trouble (PRTH)
PCU
●
30
Non-contact main thermistor differential input
abnormality (RTH1-d)
abnormality (RTH1-d)
PCU
●
H5
01
POIND not-reached jam is detected 5 times
continuously
continuously
PCU
●
H7
10
Low temperature detection in the reset operation of
temperature adjustment after alarm stop in a job
(Noncontact main the rmistor (RTH1-d))
temperature adjustment after alarm stop in a job
(Noncontact main the rmistor (RTH1-d))
PCU
●
11
Low temperature detection in the reset operation of
temperature adjustment after alarm stop in a job
(Sub thermistor (RTH2))
temperature adjustment after alarm stop in a job
(Sub thermistor (RTH2))
PCU
●
12
Low temperature detection in the reset operation of
temperature adjustment after alarm stop in a job
(Lower thermistor (RTH2))
temperature adjustment after alarm stop in a job
(Lower thermistor (RTH2))
PCU
●
L1
00
Mirror feed trouble
SCU
●
L2
10
CCD cooling fan motor trouble (SCU detection)
SCU
●
11
Lamp cooling fan motor trouble (SCU detection)
SCU
●
L3
00
Mirror return trouble
SCU
●
L4
01
Main motor lock trouble
PCU
●
02
Drum motor lock trouble
PCU
●
03
Fusing motor lock trouble
PCU
●
04
Developing motor trouble
PCU
●
08
Waste toner transport pipe lock
PCU
●
14
Toner cartridge motor lock trouble
PCU
●
15
Fusing front PG control error
PCU
●
L4
29
HDD cooling fan motor trouble
ICU
●
30
Controller fan motor trouble
ICU
●
31
Machine heat exhaust fan 1 trouble
PCU
●
32
Power cooling fan 1 / 2 trouble
PCU
●
34
Polygon cooling fan trouble
PCU
●
36
Toner suction fan trouble
PCU
●
38
Reverse transport cooling fan trouble
PCU
●
39
Reverse cooling fan trouble
PCU
●
40
Ozone exhaust fan 1 trouble
PCU
●
41
Ozone exhaust fan 2 trouble
PCU
●
43
Paper cooling fan trouble
PCU
●
46
Development cooling fan 1 trouble
PCU
●
47
Power cooling fan 3 trouble
PCU
●
48
ADU section paper cooling fan 1 trouble
PCU
●
49
ADU section paper cooling fan 2 trouble
PCU
●
50
Process cooling fan 1 trouble
PCU
●
51
Process cooling fan 2 trouble
PCU
●
52
Process cooling fan 3 trouble
PCU
●
53
Process cooling fan 4 trouble
PCU
●
54
PS cooling fan trouble
PCU
●
55
Process cooling fan trouble
PCU
●
L6
10
Polygon motor trouble
PCU
●
L8
01
NO full wave signal
ICU / P-
CON
CON
●
05
No full wave signal (PCU detection)
PCU
●
20
Power controller communication trouble
ICU
●
U1
01
Battery abnormality
ICU
●
Trouble code
Trouble code content
Remarks
Trouble
detection
Mechanism
Option
Electricity
FAX
Supply
Main
code
code
Sub
code
Click on the first or last page to see other MX-M950 / MX-MM1100 (serv.man39) service manuals if exist.