Read Sharp MX-M950 / MX-MM1100 (serv.man38) Service Manual online
MX-M1100 SIMULATION 7 – 99
127
1, 2
[Line 2] Busy tone OFF
detection time lower limit
detection time lower limit
250ms
0 0
0
250ms
140ms
0 1
0
450ms
1 0
350ms
1 1
3, 4
[Line 2] Busy tone OFF
detection time upper limit
detection time upper limit
750ms
0 0
0
750ms
650ms
0 1
0
1000ms
1 0
2850ms
1 1
5 - 8
[Line 2] Call signal OFF
non-detection time
non-detection time
Setting range
Binary input
Binary input
0 - 1500ms
100ms unit
100ms unit
0
400ms
1
0
0
0
0
128
1 - 4
[Line 2] Call signal ON time
lower limit
lower limit
Setting range
Binary input
Binary input
150 - 300ms
10ms interval
10ms interval
0
150ms
The sine wave of CI
detection is
substituted by this
switch.
detection is
substituted by this
switch.
0
0
0
0
0
5 - 8
[Line 2] Call signal ON time
upper limit
upper limit
Setting range
Binary input
Binary input
3000ms - 4500ms
100ms interval
100ms interval
0
3000ms
0
0
0
0
0
129
1 - 4
[Line 2] Call signal OFF
time lower limit
time lower limit
Setting range
Binary input
Binary input
0 - 1500ms
100ms unit
100ms unit
0
700ms
1
1
1
1
1
5, 6
[Line 2] Call signal OFF
time upper limit
time upper limit
6.5 sec
0 0
0
6.5 sec
10 sec
0 1
0
15 sec
1 0
20 sec
1 1
7
[Line 2] V.34 mode function
(including polling when
calling)
(including polling when
calling)
1: Off
0: On
0
ON
8
[Line 2] V.34 mode function
(when call-in)
(when call-in)
1: Off
0: On
0
ON
130
1
[Line 2] Dial tone ON
detection time
(when continuous
detection)
detection time
(when continuous
detection)
1: 1 sec
0: 1.5 sec
0
1.5 sec
2, 3
[Line 2] DP dial pulse
number process
number process
NORMAL
(Pulse = DIAL, 10=0)
(Pulse = DIAL, 10=0)
0 0
0
NORMAL
EXTEND
(Pulse = DIAL + 1)
(Pulse = DIAL + 1)
0 1
0
REVERSE
(Pulse = 10-DIAL)
(Pulse = 10-DIAL)
1 0
Same as 00
1 1
4
[Line 2] Dial tone detection
1: YES
0: NO
1
YES
5
[Line 2] Busy tone detection
1: NO
0: YES
0
YES
6, 7
[Line 2] Busy tone detection
cycle
cycle
2 pulse
0 0
0
3 pulse
0 1
0
4 pulse
1 0
6 pulse
1 1
8
Not Used
0
131
1 - 4
[Line 2] dial tone ON/OFF
detection time lower limit
(When continuous
detection)
detection time lower limit
(When continuous
detection)
Default
0 : 40
0 : 40
40 + N * 30
Min.: 40, Max.: 490
Min.: 40, Max.: 490
0
100ms
Enable only when
DT detection
continue
DT detection
continue
0
1
0
1
0
5 - 8
[Line 2] Dial tone ON/OFF
detection time upper limit
(When continuous
detection)
detection time upper limit
(When continuous
detection)
Default
0 : 400
0 : 400
400 + N * 100
Min.: 400, Max.: 1900
Min.: 400, Max.: 1900
0
Enable only when
DT detection
continue
DT detection
continue
0
1
1
1
1
132
1 - 8
Not used
0
0
0
1
0
0
1
1
0
0
1
0
0
1
1
SW
No.
No.
Bit
No.
System
settings
Item
SW selection and function
Initial value
Remarks
Click on the first or last page to see other MX-M950 / MX-MM1100 (serv.man38) service manuals if exist.