MX-M950, MX-MM1100 (serv.man38). Section 7 Simulation - Sharp Copying Equipment Service Manual (repair manual). Page 94

Read Sharp MX-M950 / MX-MM1100 (serv.man38) Service Manual online

MX-M1100  SIMULATION  7 – 94
91
1, 2
LVCS monitoring cycle
0ms (Do not monitor)
0 0
1
20ms
10ms
0 1
0
20ms
1 0
30ms
1 1
3
Not function
[Line 1] Line echo cancel
0: Echo cancel NO
1: Echo cancel YES
0
0: Echo cancel 
NO
4
Not function
[Line 1] Audio echo cancel
0: Echo cancel NO
1: Echo cancel YES
0
0: Echo cancel 
NO
5 - 8
Not used
0
0
0
0
92
1 - 4
External connection volume
Setting range
0: 0dBm
0 to 8: -3.0dBm intervals
8 to 12: -4.0dBm intervals
12 to 14: -8.0dBm intervals
15: 
∞ (mute)
0
-12.0dBm
Remote selection 
sound
1
0
0
5 - 8
Not used
0
0
0
0
93
|
97
1 - 8
Not used
0
98
1 - 5
Not used
1
1
0
1
0
6
Setting of timeout 
monitoring between frames
0: Monitor
1: Do not monitor
0
Monitor
7, 8
Modem lightning protection 
measures
0 second
0 0
"01": 20 second 
(only for Europe, 
Australia, South 
Africa)
"00": 0 second (Other  
than the above)
20 seconds
0 1
30 seconds
1 0
40 seconds
1 1
99
1 - 8
Not used
0
100
1 - 8
CNG detection completion 
time
Setting range
0: Unlimited
1 to 255 seconds
0
45 seconds
0
1
0
1
1
0
1
101
|
102
1 - 8
Not used
0
103
1 - 4
External connection number 
setting 1 <1st digit>
Registration number regulation:
0 - 9 / *(a) / #(b) / - (Pause) (c) / 
Following digits: Not used (d) / Anything OK (f)
0
0
Support from BOX 
Ver01.03.
When e is set, 
default is used.
0
0
0
5 - 8
External connection number 
setting 1 <2nd digit>
Registration number regulation:
0 - 9 / *(a) / #(b) / - (Pause) (c) / 
Following digits: Not used (d) / Anything OK (f)
0
0
When e is set, 
default is used.
0
0
0
104
1 - 4
External connection number 
setting 1 <3rd digit>
Registration number regulation:
0 - 9 / *(a) / #(b) / - (Pause) (c) / 
Following digits: Not used (d) / Anything OK (f)
0
0
When e is set, 
default is used.
0
0
0
5 - 8
External connection number 
setting 1 <4th digit>
Registration number regulation:
0 - 9 / *(a) / #(b) / - (Pause) (c) / 
Following digits: Not used (d) / Anything OK (f)
0
0
When e is set, 
default is used.
0
0
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value
Remarks
Page of 103
Display