MX-M1100  SIMULATION  7 – 97
116
1, 2
[Line 2] Send/receive 
coding capacity 
(Communication other than 
V.34)
(Reflected on DIS/DCS/
DTC)
JBIG/MMR/MR/MH
0 0
0
JBIG/MMR/MR/
MH
MMR/MR/MH
0 1
0
MR/MH
1 0
MH
1 1
3 - 6
[Line 2] MODEM send 
speed (Other than V.34) 
(DCS)
V.27ter  2400bps
0 0 0 0
1
V.17 14400bps
* For mark bit, set to 
V.17 14400 bps.
Setting for 
communication 
other than V.34
V.29  9600bps
0 0 0 1
0
V.27ter 4800bps
0 0 1 0
0
V.29  7200bps
0 0 1 1
0
V.33  14400bps
0 1 0 0
*
0  1  0  1
V.33  12000bps
0 1 1 0
*
0  1  1  1
V.17  14400bps
1 0 0 0
V.17   9600bps
1 0 0 1
V.17  12000bps
1 0 1 0
V.17   7200bps
1 0 1 1
*
1  1  0  0
*
1  1  0  1
*
1  1  1  0
*
1  1  1  1
7, 8
[Line 2] MODEM speed 
fixed when receiving (Other 
than V.34)
(DIS)
Fixed to NO
0 0
0
Fixed to NO
Setting for 
communication 
other than Super 
G3
Max. speed when 
receive
V.29-9600bps
0 1
0
V.27ter-4800bps
1 0
V.17-14400bps
1 1
117
1
Adjustment 
value
[Line 2] Signal send level
For setting over the max. 
send level, set to the max. 
value of the destination. 
Binary input
When set to 22 - 225, 
the operation is 
executed as setting of 
21.
The send level to the line 
is virtually same as the 
set value. 
Set value is 0 - 21
0
-10dBm
-8dBm
2
0
3
0
4
0
5
1
6
0
7
1
8
0
118
1 - 4 
Not  used
1
0
0
0
5 - 8
FAX initial 
setting
[Line 2] Auto receive call 
number setting
Binary input
0
2 times
No ring for 0 time 
setting
Receive (However, 
except for nighttime 
FAX mode)
Setting range:
Japan / North America / 
Taiwan / India
0 - 15 times
0
Europe / Indonesia / 
Thailand
0 - 9 times
1
Australia / NZL
2 - 4 times
0
119
1, 2
Not used
0
0
3
[Line 2] DPMUTE control
1:  ON
0: OFF
0
OFF
4
[Line 2] DTMF signal send 
time
Setting range
Binary input
710 - 310ms
10ms unit
0
110ms
When set to "69ms 
or less," the default 
value of "110ms" is 
used. 
5
1
6
0
7
1
8
1
120
1
Adjustment 
value
[Line 2] DTMF minimum 
pause time setting
Setting range
Binary input
50 -255ms
1ms interval
0
120ms
When set to "49ms 
or less," the default 
value of "120ms" is 
used. 
2
1
3
1
4
1
5
1
6
0
7
0
8
0
SW 
No.
Bit 
No.
System 
settings
Item
SW selection and function
Initial value