MX-M1100 SELF DIAG AND TROUBLE CODE  8 – 23
 
H4-02
Lower thermistor low temperature 
trouble (PRTH)
 
H4-30
Non-contact main thermistor 
differential input abnormality (RTH1-d)
 
H5-01
POIND not-reached jam is detected 
5 times continuously
 
H7-10
Low temperature detection in the 
reset operation of temperature adjust-
ment after alarm stop in a job 
(Noncontact main thermistor(RTH1-d))
 
H7-11
Low temperature detection in the 
reset operation of temperature adjust-
ment after alarm stop in a job 
(Sub thermistor (RTH2))
 
H7-12
Low temperature detection in the 
reset operation of temperature adjust-
ment after alarm stop in a job 
(Lower thermistor (RTH2))
 
L1-00
Mirror feed trouble
Detail
The set temperature is not reached with the specified 
time after turning on the power relay
Section
PCU
Cause
Thermistor trouble. Heater lamp trouble. 
PCU PWB trouble. Thermostat trouble.
AC power source trouble. 
Interlock switch trouble
Check & 
Remedy
Check blinking of the heater lamp with Sim. 5-2. 
If the lamp blinks normally, check the thermistor and the 
harness. 
Check the thermistor input circuit section of the PCU 
PWB. If the lamp does not light up, check the heater 
lamp and the thermostat for breakage. 
Check the interlock switch. 
Check the AC PWB and the PCU PWB lamp control 
circuit. Cancel the trouble with Sim. 14. 
Detail
The differential value does not rise above the specified 
level within the specified time from turning ON the HL1. 
Section
PCU
Cause
Thermistor trouble, heater lamp trouble, PCU PWB 
trouble, thermostat trouble, AC power trouble. Interlock 
switch trouble.
Check & 
Remedy
Use Sim. 5-2 to check the flashing operation of the 
heater lamp. If the heater lamp flashes normally, check 
the thermistor and the harness. 
Check the thermistor input circuit section of the PCU 
PWB. If the heater lamp does not light up, check for 
disconnection of the heater lamp or the thermostat. 
Check the interlock switch. 
Check the lamp control circuit of the AC PWB and the 
PCU PWB. Use Sim. 14 to cancel the trouble. 
Detail
POD1 not-reached jam is detected 5 times 
continuously. 
Section
PCU
Cause
A fusing jam is not canceled completely. (Jam paper 
remains.)
POD1 sensor trouble or harness connection trouble. 
Fusing unit instillation trouble.
Check & 
Remedy
Check the fusing section jam paper. (winding, etc.) 
Check the POD1 sensor harness. 
Check installation of the fusing unit. 
Cancel the trouble with Sim. 14. 
Detail
When in fusing alarm stopping, the specified 
temperature is not reached within the specified time. 
* Alarm stop: When the fusing temperature lowers than 
the specified level in a print job, the job is interrupted 
temporarily and temperature reset is performed. 
Section
PCU
Cause
Thermistor trouble, thermostat trouble, heater lamp 
trouble, PCU PWB trouble, AC power trouble, interlock 
switch trouble, connector and harness connection 
trouble.
Check & 
Remedy
Use Sim. 5-2 to check the ON operation of the heater 
lamp. Check conduction of the thermostat. Replace the 
heater lamp, the PCU PWB, and the AC PWB. Check 
connection of the connector and the harness. 
Detail
When in fusing alarm stopping, the specified 
temperature is not reached within the specified time. 
* Alarm stop: When the fusing temperature lowers than 
the specified level in a print job, the job is interrupted 
temporarily and temperature reset is performed. 
Section
PCU
Cause
Thermistor trouble, thermostat trouble, heater lamp 
trouble, PCU PWB trouble, AC power trouble, interlock 
switch trouble, connector and harness connection 
trouble.
Check & 
Remedy
Use Sim. 5-2 to check the ON operation of the heater 
lamp. 
Check conduction of the thermostat. Replace the heater 
lamp, the PCU PWB, and the AC PWB. 
Check connection of the connector and the harness.
Detail
When in fusing alarm stopping, the specified 
temperature is not reached within the specified time. 
* When in fusing alarm stopping, the specified 
temperature is not reached within the specified time. 
Section
PCU
Cause
Thermistor trouble, thermostat trouble, heater lamp 
trouble, PCU PWB trouble, AC power trouble, interlock 
switch trouble, connector and harness connection 
trouble.
Check & 
Remedy
Use Sim. 5-2 to check the ON operation of the heater 
lamp. Check conduction of the thermostat. Replace the 
heater lamp, the PCU PWB, and the AC PWB. 
Check connection of the connector and the harness. 
Detail
Mirror feed is not completed within the specified time
Section
SCU
Cause
Mirror unit trouble. The mirror wire is disengaged.
Circuit trouble.
Check & 
Remedy
Use Sim. 1-1 to check the operation of the mirror. 
Check the mirror motor related circuits (SCN-Mother 
PWB, SCNCNT PWB, MHP sensor PWB). 
Page of 33