MX-M850 (serv.man38). Section 8 Self Diagnostics Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 24

Read Sharp MX-M850 (serv.man38) Service Manual online

MX-M1100 SELF DIAG AND TROUBLE CODE  8 – 24
 
L2-10
CCD cooling fan motor trouble 
(SCU detection)
 
L2-11
Lamp cooling fan motor trouble 
(SCU detection)
 
L3-00
Mirror return trouble
 
L4-01
Main motor lock trouble
 
L4-02
Drum motor lock trouble
 
L4-03
Fusing motor lock trouble
 
L4-04
Developing motor trouble
 
L4-08
Waste toner transport pipe lock
 
L4-14
Toner cartridge motor lock trouble
Detail
The lock signal is detected during rotation of the fan / 
The non-lock state is detected when the motor is not 
rotated in booting
Section
SCU
Cause
Fan motor trouble, fan motor related harness and circuit 
trouble.
Check & 
Remedy
Check the fan motor related circuits (SCN-Mother PWB, 
SCNCNT PWB) and their harness and connector. 
Detail
The lock signal is detected during rotation of the fan / 
The non-lock state is detected when the motor is not 
rotated in booting
Section
SCU
Cause
Fan motor trouble, fan motor related harness and circuit 
trouble.
Check & 
Remedy
Check the fan motor related circuits (SCN-Mother PWB, 
SCNCNT PWB) and their harness and connector. 
Detail
Mirror return is not completed within the specified time
Section
SCU
Cause
Mirror unit trouble. The mirror wire is disengaged.
Circuit trouble.
Check & 
Remedy
Use Sim. 1-1 to check the operation of the mirror. 
Check the mirror motor related circuits (SCN-Mother 
PWB, SCNCNT PWB, MHP sensor PWB). 
Detail
The motor lock signal is detected during rotation of the 
main motor (MM/MM2)
Section
PCU
Cause
Main motor (MM/MM2) lock trouble.
Connection failure or disconnection of the connector 
and the harness. 
Control circuit trouble.
Check & 
Remedy
Use Sim. 6-1 to check the operation of the main motor 
(MM/MM2) lock.
Check the harness and the connector. (between the 
PCU PWB and the motor, between the HL PWB and the 
motor)
Detail
When warming up, the paper feed motor is rotated 
when canceling a jam, the lock signal is not detected 
within 1sec. 
Section
PCU
Cause
Paper feed motor trouble.
Harness connection trouble between the PCU PWB and 
the paper feed motor. 
Control circuit trouble.
Check & 
Remedy
Check the paper feed motor operation with Sim. 6-1. 
Check connection of the connector and the harness 
between the PCU PWB and the paper feed motor. 
Detail
The motor lock signal is detected during rotation of the 
fusing motor
Section
PCU
Cause
Fusing motor trouble. 
Harness connection trouble between the PCU PWB and 
the developing motor.
Control circuit trouble.
Check & 
Remedy
Check the fusing motor operation with Sim. 6-1. 
Check connection of the harness and the connector 
between the PCU PWB and the developing motor. 
Detail
The motor lock signal is detected during rotation of the 
developing motor
Section
PCU
Cause
Developing motor trouble. 
Harness connection trouble between the PCU PWB and 
the developing motor. 
Control circuit trouble.
Check & 
Remedy
Check the developing motor operation with Sim. 25-1. 
Check connection of the connector and the harness 
between the PCU PWB and the developing motor. 
Detail
Waste toner lock is detected during rotation of the drum 
motor. 
Section
PCU
Cause
Waste toner transport pipe lock. (clogging)
Waste toner lock sensor trouble.
Waste toner lock detection mechanism trouble.
Check & 
Remedy
Use Sim. 6-1 to check the operations of the drum motor. 
Check for clogging in the waste toner transport pipe.
Check the waste toner lock sensor.  
Detail
Though the toner cartridge motor is rotated for a certain 
time, the toner cartridge motor rotation sensor count 
value does not exceed the threshold value
Section
PCU
Cause
Toner cartridge motor trouble.
Toner cartridge motor rotation sensor trouble.
Harness connection trouble between the PCU PWB and 
the toner cartridge motor.
Harness trouble between the PCU PWB and the toner 
cartridge motor rotation sensor.
Toner cartridge trouble.
Check & 
Remedy
Use Sim. 10-1 to check the operation of the toner 
cartridge motor. 
Use Sim. 10-3 to check the operation of the toner 
cartridge motor rotation sensor. 
Check the harness and the connector between the PCU 
PWB and the toner cartridge motor. 
Check the harness and the connector between the PCU 
PWB and the toner cartridge motor rotation sensor. 
Replace the toner cartridge.