MX-M350N, MX-M350U, MX-M450N, MX-M450U (serv.man8). Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 10

Read Sharp MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man8) Service Manual online

MX-M350/M450 N/U  TROUBLE CODES  11 - 10
H5
01
Content
5-time continuous POD1 not-reaching 
jam detection
Detail
5-time continuous POD1 not-reaching 
jam detection
Cause
A fusing section jam is not properly 
removed. (Jam paper remains.)
POD1 sensor trouble, or harness 
disconnection
Improper installation of fusing unit
Check and 
remedy
Check jam paper in the fusing section. 
(winding, etc.)
Check POD1 sensor harness, and 
check  the fusing unit installation.
Use SIM14 to cancel the trouble.
L1
00
Content
Scanner feed trouble
Details
Scanner feed is not completed within 
the specified time.
Cause
Scanner unit abnormality
Scanner wire disconnection
Check & 
Remedy
Check scanning with SIM 1-1.
L3
00
Content
Scanner return trouble
Details
Scanner return is not completed within 
the specified time.
Cause
Scanner unit abnormality
Scanner wire disconnection
Check & 
Remedy
Check scanning with SIM 1-1.
L4
01
Content
Main motor lock detection
Detail
The motor lock signal is detected for 
1.5sec during rotation of the main 
motor.
Cause
main motor trouble
Check connection of harness between 
the PCU PWB and the main motor. 
Control circuit trouble
Check and 
remedy
Use SIM25-1 to check the main motor 
operation.
Check harness and connector between 
the PCU PWB and the main motor.
02
Content
Drum motor lock detection
Detail
The motor lock signal is detected for 
1.5sec during rotation of the drum 
motor.
Cause
Drum motor trouble
Improper connection of harness 
between the PCU PWB and the drum 
motor.
Control circuit trouble
Check and 
remedy
Use SIM6-1 to check the drum motor 
operation.
Check harness and connector between 
the PCU PWB and the drum motor.
MAIN SUB
Details
L4
30
Content
Controller fan motor lock detection
Detail
The motor lock signal is detected 
during rotation of the controller fan 
motor.
The motor lock signal is detected 
during rotation of the HDD fan motor.
Cause
Fan motor trouble
Improper connection of the harness 
between the controller PWB and the 
fan motor.
Control circuit trouble
Check and 
remedy
Use SIM 6-2 to check the fan motor 
operation.
Check the harness and the connector 
between the controller PWB and the 
fan motor.
L6
10
Content
Polygon motor lock detection
Detail
It is judged that the polygon motor lock 
signal is not outputted.
Lock signal is checked in the interval of 
10sec after starting the polygon motor, 
and it is judged that the polygon motor 
does not rotate normally.
Cause
The LSU connector or harness in the 
LSU is disconnected or broken.
Polygon motor trouble
Check and 
remedy
Use SIM61-1 to check the polygon 
motor operation.
Check connector and harness 
connection.
Replace LSU.
L8
01
Content
No fullwave signal
Detail
Full wave signal is not detected.
Cause
The PCU PWB connector or the power 
unit harness is disconnected or broken.
PCU PWB trouble
12V power source trouble
Check and 
remedy
Check connection of the harness and 
connector.
Replace PCU PWB.
Replace the power unit.
Replace the controller connection 
mother board.
02
Content
Full wave signal width abnormality
Detail
It is judged as full wave signal 
frequency abnormality. 
(When the detection cycle is judged as 
69Hz or above or 42.5Hz or below)
Cause
The connector or harness of the PCU 
PWB and the power PWB is 
disconnected.
PCU PWB trouble
Power unit trouble
Check and 
remedy
Check connection of the harness and 
connector.
Replace the PCU PWB.
Replace the power unit. 
MAIN SUB
Details
Page of 15
Display