MX-M350N, MX-M350U, MX-M450N, MX-M450U (serv.man8). Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 11

Read Sharp MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man8) Service Manual online

MX-M350/M450 N/U  TROUBLE CODES  11 - 11
U1
01
Content
FAX battery abnormality
Detail
FAX backup SRAM battery voltage fall
Cause
Battery life
Battery circuit abnormality
Check and 
remedy
Check that the battery voltage is about 
2.5V or above.
Check the battery circuit. 
02
Content
RTC read abnormality 
(common with FAX, on ICU PWB)
Details
The value read from RTC on ICU PWB 
is [EE]h (abnormal).
Cause
RTC circuit abnormality
Battery voltage fall
Battery circuit abnormality
Check & 
Remedy
Set the time again with key operation, 
and check that time advances properly.
Check RTC circuit.
Check that battery voltage is about 
2.5V or above.
Check battery circuit. 
U2
00
Content
EEPROM read/write error (ICU)
Detail
EEPROM write error
Cause
EEPROM trouble
EEPROM is not initialized.
ICU PWB EEPROM access circuit 
trouble
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Save the counter/adjustment values 
with the  simulation.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
U2
11
Content
Counter check sum error (ICU)
Detail
Counter data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
ICU PWB EEPROM access circuit 
trouble
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Save the counter/adjustment values 
with the  DIAG simulation.
Use DIAG (SIM16) to cancel U2 
trouble.
Replace the ICU PWB.
12
Content
Adjustment value check sum error 
(ICU)
Detail
Adjustment data area check sum error
Cause
EEPROM trouble
Control circuit trouble by noise
ICU PWB EEPROM access circuit 
trouble
Check and 
remedy
Check that EEPROM is properly 
inserted. 
Save the counter/adjustment values 
with the  simulation.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
MAIN SUB
Details
U2
22
Content
SRAM memory check sum error (ICU)
Detail
MFPC section SRAM memory check 
sum error
Cause
SRAM trouble
Control circuit runaway due to noises
ICU PWB SRAM access circuit trouble
Check and 
remedy
Initialize the communication 
management table registered in the 
SRAM and the FAX soft switch.
Since the registered data are deleted, 
register the data again.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
23
Content
SRAM memory individual data check 
sum error (ICU)
Detail
Check sum error for every data in the 
SRAM memory of the MFPC section
(Communication management table, 
sender registration data, etc.)
Cause
SRAM trouble
Control circuit runaway due to noises
ICU PWB SRAM access circuit trouble
Check and 
remedy
Automatically initialize the data related 
to the check sum error by turning OFF/
ON the power.
Since the registered data are deleted, 
register the data again.
Use SIM16 to cancel U2 trouble.
Replace the ICU PWB.
U2
50
Content
HD section individual data check sum 
error (ICU)
Detail
Check sum error for every individual 
data in HD of the MFPC section (One-
touch, Group, Program, etc.)
Cause
HDD write/read error
Control circuit runaway due to noises
ICU PWB HD access circuit trouble
Check and 
remedy
Automatically initialize the data related 
to the check sum error by turning OFF/
ON the power.
Since the registered data are deleted, 
register the data again.
Use SIM 16 to cancel the U2 trouble.
Replace the HD PWB.
Replace the ICU PWB.
80
Content
EEPROM read/write error (Scanner)
Details
Scanner EEPROM write error
Cause
EEPROM abnormality
Scanner PWB EEPROM access circuit 
abnormality
Check & 
Remedy
Check that EEPROM is set properly.
Record counter/adjustment values with 
the simulation to protect the data from 
being deleted.
Cancel U2 trouble with SIM 16.
Replace scanner PWB.
MAIN SUB
Details
Page of 15
Display

Click on the first or last page to see other MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man8) service manuals if exist.