MX-M350N, MX-M350U, MX-M450N, MX-M450U (serv.man8). Trouble Codes - Sharp Copying Equipment Service Manual (repair manual). Page 3

Read Sharp MX-M350N / MX-M350U / MX-M450N / MX-M450U (serv.man8) Service Manual online

MX-M350/M450 N/U  TROUBLE CODES  11 - 3
3. Details of trouble codes
U7
00 RIC communication trouble
Controller
CH
--
Door open (CH ON)
PCU
00 No developer cartridge
PCU
01 No toner cartridge
PCU
02 No drum cartridge
PCU
EE EL Auto developer adjustment 
trouble (Over-toner)
Only during 
DIAG
PCU
EU Auto developer adjustment 
trouble (Under-toner)
Only during 
DIAG
PCU
PC
--
Personal counter not 
installed
Controller
PF
--
RIC copy inhibit signal is 
received.
Controller
--
--
Auditor not ready
Controller
MAIN SUB
Details
C1
00
Content
MC trouble
Detail
Main charger output abnormality 
(Output open)
Trouble signal is outputted from the 
high voltage transformer.
Cause
The main charger is not installed 
properly.
The main charger is not assembled 
properly.
Disconnection of connector of high 
voltage transformer.
High voltage harness disconnection or 
breakage.
Check and 
remedy
Use the SIM 8-2 to check the main 
charger output.
Check for disconnection of the main 
charger. 
Replace the high voltage unit. 
E6
11
Content
CSI shading trouble (White correction)
Details
The CIS white reference plate scan 
level is abnormal when the lamp is on.
Cause
Abnormal harness installation to CIS 
unit
Dirt on the white reference plate.
CIS lighting error
CIS unit installation trouble
CIS unit abnormality
Scanner PWB abnormality
Check & 
Remedy
Clean the white reference plate. 
Check CIS light quantity (SIM 5-3) and 
lighting. 
Check CIS unit harness.
Check scanner PWB. 
14
Content
CIS communication trouble
Details
Communication trouble (clock sync) 
between scanner PWB and CIS-ASIC
Cause
Abnormal harness installation to CIS 
unit
CIS unit abnormality
Scanner PWB abnormality
Check & 
Remedy
Check CIS unit harness.
Check CIS unit.
Check scanner PWB. 
Trouble 
codes
Contents
Remark
Trouble 
detection
E7
01
Content
System data trouble
Detail
When in data storage/acquiring of the 
HDD system area, the HDD responds 
an error and does not respond for 
30sec, it is judged as a trouble.
Cause
The HDD is not properly installed to the 
ICU PWB.
The HDD does not work for the ICU 
PWB.
ICU PWB abnormality
Check and 
remedy
Check installation of the HDD to the 
ICU PWB.
Check harness connection of the HDD 
from the ICU PWB.
Use SIM62-2, 3 to check the HDD 
read/write.
Replace the HDD.
Replace the ICU PWB.
E7
02
Content
Laser trouble
Detail
BD signal from LSU is kept OFF, or ON.
Cause
The connector of LSU or the harness in 
LSU is disconnected or broken.
The polygon motor does not rotate 
normally.
The laser home position sensor in LSU 
is shifted.
The proper voltage is not supplied to 
the power line for laser.
Laser emitting diode trouble
PCU PWB trouble
ICU PWB trouble
Check and 
remedy
Check for disconnection of the LSU 
connector.
Use SIM 61-1 to check LSU operation.
Check that the polygon motor rotates 
normally or not.
Check light emission of laser emitting 
diode.
Replace the LSU unit.
Replace the PCU PWB.
Replace the ICU PWB.
03
Content
HDD trouble
Detail
HDD connection failure
If the HDD responds an error or does 
not respond for 30sec, it is judged as 
an error. (Other than the system area)
Data abnormality in the file 
management area (when the cluster 
chain is broken)
Cause
HDD is not installed properly to the ICU 
PWB.
HDD does not operate properly in the 
ICU PWB.
ICU PWB trouble
Check and 
remedy
Check installation of HDD to the ICU 
PWB.
Check connection of the harness of 
HDD to the ICU PWB. 
Use SIM 62-2, -3 to check read/write of 
HDD.
Replace HDD.
Replace ICU PWB. 
MAIN SUB
Details
Page of 15