Read Sharp MX-M260 / MX-M260N / MX-M260FG / MX-M260FP (serv.man2) Handy Guide online
17
Test Simulations
1.Entering the simulation mode
Perform the following procedure to enter the simulation mode.
Main code [START] key then Sub code [START] key
2. Cancelling the simulation mode
When the clear all key is pressed, the simulation mode is cancelled.
When the interruption key is pressed, the process is interrupted and the screen
returns to the sub code entering display.
After cancelling the simulation mode, be sure to turn OFF/ON the power and check
the operation.
Note: If the machine is terminated by a jam error or paper empty during copying in
the adjustment by the simulation, recopying is required.
Note: The values in the simulation columns are not default values but sample values.
When the interruption key is pressed, the process is interrupted and the screen
returns to the sub code entering display.
After cancelling the simulation mode, be sure to turn OFF/ON the power and check
the operation.
Note: If the machine is terminated by a jam error or paper empty during copying in
the adjustment by the simulation, recopying is required.
Note: The values in the simulation columns are not default values but sample values.
Main Sub
Contents
01
01
Used to check the operation of the scanner unit and its control
circuit.
circuit.
02
Used to check the operation of sensor and detector in the scanning
(read) section and the related circuit.
(read) section and the related circuit.
02
01
Used to check the operation of the RSPF unit and the related
circuit.
circuit.
02
Used to check the operation of sensors and detectors in the RSPF
unit and the related circuit.
unit and the related circuit.
03
Used to check the operation of the loads in the RSPF unit and the
control circuits.
control circuits.
03
02
Used to check the operation of sensor and detector in the finisher
and the related circuit.
and the related circuit.
03
Used to check the operation of the load in the finisher and the
control circuit.
control circuit.
10
Used to make each adjustment of the finisher.
Click on the first or last page to see other MX-M260 / MX-M260N / MX-M260FG / MX-M260FP (serv.man2) service manuals if exist.