Read Sharp MX-LC13 (serv.man27) Technical Bulletin online
MX-7500N MX-LC13 (LARGE CAPACITY TRAYS) 9 – 16
NOTE: Note for separation
When separating, tighten the screw to release the lock.
When connecting again, loosen the screw after connection.
When connecting again, loosen the screw after connection.
C. Connect the cable
1) Remove the cover of LCT.
2) Cut the rear cabinet with using nipper or cutter to make a hole,
and then wire the harness through the hole.
3)
Connect the harness inside the large capacity trays, tighten
the screw(RB14 Packed Item No.13), and pass the harness
through the clamp.
the screw(RB14 Packed Item No.13), and pass the harness
through the clamp.
4)
Fix the cover with the screw.
5)
Connect the connector from LCT to the paper pass unit and
tighten the screw.
tighten the screw.
Click on the first or last page to see other MX-LC13 (serv.man27) service manuals if exist.