MX-FXX2 (serv.man2). MX-FXX2 Service Manual (Complete) - Sharp Copying Equipment Service Manual (repair manual). Page 21

Read Sharp MX-FXX2 (serv.man2) Service Manual online

MX-FXX2  SIMULATIONS, FAX SOFTWARE SWITCH  5 – 10
Check item
The number in < > indicates the line.
 
66-4
Purpose
Operation test/Check
Function (Purpose) Used to send the selected signals to the
line and the main unit speaker. (Send level:
max.) 
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-04, the screen on the
right is displayed. (Default, left upper selected.)
* Use [
↑] [↓] buttons to switch the send mode select page.
When the selected item is the top (last)item, [
↑] [↓] buttons
gray out. (The highlighted section of the set value is
switched and displayed on the set setting area.)
When [
↑] [↓] buttons gray out, they are disabled.
2)
When a button of a signal to be sent is selected, it is high-
lighted and the previously set button is shifted to the normal
display.
* Only one signal to be sent can be selected.
3)
When [EXECUTE] button is pressed, it is highlighted and sig-
nals are sent.
4)
To end signal send:
When [EXECUTE] button is pressed, it is highlighted and sig-
nal send is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display returns
to the sub number entry screen.
<Signal send table>
Page1
Page2
 
66-5
Purpose
Operation test/Check
Function (Purpose) Used to send the selected signal to the line
and the main unit speaker. (Send level: Soft
SW setting) (For the kinds of send signals,
refer to PART1 and PART2 of SIM66-04.)
Section
FAX
Item
Operation
Operation/Procedure
1)
When the machine enters Simulation 66-05, the following
screen is displayed. (Default, left upper selected)
* Use  [
↑] [↓] buttons to switch the send mode select page.
When the selected item is the top (last)item, [
↑] [↓] buttons
gray out. (The highlighted section of the set value is
switched and displayed on the set setting area.)
When [
↑] [↓] buttons gray out, they are disabled.
2)
When a button of a signal to be sent is selected, it is high-
lighted and the previously set button is shifted to the normal
display.
* Only one signal to be sent can be selected.
3)
When [EXECUTE] button is pressed, it is highlighted and sig-
nals are sent.
4)
To end signal send:
* When [EXECUTE] button is pressed, it is highlighted and
signal send is interrupted.
* When [CA] key is pressed, the simulation is terminated.
* When [SYSTEM SETTINGS] key is pressed, the display
returns to the sub number entry screen.
Check memory item
Remark
1
All Memory Device Check (once)
All the items are checked 
once. 
2
MFP SRAM (once)
Check only once
3
MFP SRAM (repeat)
Repeat check
4
MFP FLASH + OP.FLASH (once)
Check only once
5
MFP FLASH + OP.FLASH (repeat)
Repeat check
6
MODEM EEPROM <1> (once)
Check only once in LINE1
7
MODEM EEPROM <1> (repeat)
Repeat check in LINE1
8
MODEM SDRAM <1> (once)
Check only once in LINE1
9
MODEM SDRAM<1>(repeat)
Repeat check in LINE1
NOSIGNAL
33.6 V34
31.2 V34
28.8 V34
26.4 V34
24.0 V34
21.6 V34
19.2 V34
16.8 V34
14.4 V34
12.0 V34
9.6 V34
7.2 V34
4.8 V34
2.4 V34
14.4 V33
12.0 V33
14.4 V17
12.0 V17
9.6 V17
7.2 V17
9.6 V29
7.2 V29
4.8 V27t
2.4 V27t
0.3 FLG
CED 2100
CNG 1100
0.3 V21
ANSam
RINGER
No RBT
SIMULATION NO.66-03
CLOSE
TEST
FAX PWB MEMORY CHECK
0
ALL Memory Device Check(once)
MFP SRAM(once)
MFP SRAM(repeat)
MFP FLASH+OP.FLASH(once)
MFP FLASH+OP.FLASH(repeat)
MODEM EEPROM<1>(once)
MODEM EEPROM<1>(repeat)
MODEM SDRAM<1>(once)
MODEM SDRAM<1>(repeat)
1/1
DP MAKE
DP BRK
NO MSG
SIMULATION NO.66-04
CLOSE
TEST
SIGNAL OUTPUT CHECK.(LEVEL MAX)
0
EXECUTE
1/2
NOSIGNAL
33.6V34
28.8V34
31.2V34
26.4V34
24.0V34
19.2V34
21.6V34
16.8V34
14.4V34
9.6V34
12.0V34
7.2V34
4.8V34
14.4V33
2.4V34
12.0V33
14.4V17
9.6V17
12.0V17
7.2V17
9.6V29
4.8V27t
7.2V29
2.4V27t
0.3FLG
CNG1100
CED2100
0.3V21
AVSam
No RBT
RINGER
SIMULATION NO.66-05
CLOSE
TEST
SIGNAL OUTPUT CHECK.(SOFT SW.)
0
EXECUTE
1/2
NOSIGNAL
33.6V34
28.8V34
31.2V34
26.4V34
24.0V34
19.2V34
21.6V34
16.8V34
14.4V34
9.6V34
12.0V34
7.2V34
4.8V34
14.4V33
2.4V34
12.0V33
14.4V17
9.6V17
12.0V17
7.2V17
9.6V29
4.8V27t
7.2V29
2.4V27t
0.3FLG
CNG1100
CED2100
0.3V21
AVSam
No RBT
RINGER
Page of 80
Display