MX-FX10. Service Manual. - Sharp Copying Equipment Service Manual (repair manual). Page 59

Read Sharp MX-FX10 Service Manual online

MX-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 4-49
114 1-4 Scan effective 
image area (OC) 
Sub scanning Lead 
edge image loss
Binary input
Setting range: -56 - +56 lines  1step = 8 lines
0 line
5-8 Scan effective 
image area (OC) 
Sub scanning Rear 
edge image loss
Binary input
Setting range: -56 - +56 lines  1step = 8 lines
For Bit No., refer to the table of SW114-(1 - 4).
0 line
115 1-4 Scan effective 
image area (OC) 
Main scanning left 
edge image loss
Binary input
Setting range: -56 - +56 lines  1step = 8 lines
For Bit No., refer to the table of SW114.
0 dot
5-8 Scan effective 
image area (OC) 
Main scanning right 
edge image loss
Binary input
Setting range: -56 - +56 lines  1step = 8 lines
For Bit No., refer to the table of SW114.
0 dot
116 1-8 Scanning 
magnification ratio 
adjustment OC 
(Main scanning)
Binary input
Setting range: -12.7% - +12.7%  1step = 0.1% 
For Bit No., refer to the table of SW112.
0%
117 1-8 Scanning 
magnification ratio 
adjustment OC (Sub 
scanning)
Binary input
Setting range -12.7% - +12.7%  1step = 0.1% 
For Bit No., refer to the table of SW112.
0%
118 1-4 Scan effective 
image area (SPF), 
Sub scanning, Lead 
edge image loss
Binary input
Setting range -12.7 - +12.7 lines  1step = 8 lines
For Bit No., refer to the table of SW114.
0 line
5-8 Scan effective 
image area (SPF), 
Sub scanning, Rear 
edge image loss
Binary input
Setting range: -14 - +14 lines  1step = 2 lines
0 line
119 1-4 Scan effective 
image area (SPF), 
Main scanning, Left 
edge image loss
Binary input
Setting range: -56 - +56dots  1step = 8dots
For Bit No., refer to the table of SW114.
 
(However, the unit of a set value is dots.)
0 dot
5-8 Scan effective 
image area (SPF), 
Main scanning, 
Right edge image 
loss
Binary input
Setting range: -56 - +56dots  1step = 8dots
For Bit No., refer to the table of SW114.
 
(However, the unit of a set value is dots.)
0 dot
SW
No.
Bit 
No.
Item
Switch serection and function
Initial value
System 
settings
Bit No.
Setting 
value
1
2
3
4
0
0
0
0
0  line
0
0
0
1
+8  lines
0
0
1
0
+16  lines
0
0
1
1
+24  lines
0
1
0
0
+32  lines
0
1
0
1
+40  lines
0
1
1
0
+48  lines
0
1
1
1
+56  lines
1
0
0
0
0  line
1
0
0
1
-8  lines
1
0
1
0
-16 lines
1
0
1
1
-24 lines
1
1
0
0
-32 lines
1
1
0
1
-40 lines
1
1
1
0
-48 lines
1
1
1
1
-56 lines
Bit No.
Setting 
value
1
2
3
4
Bit No.
Setting 
value
5
6
7
8
0
0
0
0
0  line
0
0
0
1
+2  lines
0
0
1
0
+4  lines
0
0
1
1
+6  lines
0
1
0
0
+8  lines
0
1
0
1
+10  lines
0
1
1
0
+12  lines
0
1
1
1
+14  lines
1
0
0
0
0 line
1
0
0
1
-2  lines
1
0
1
0
-4  lines
1
0
1
1
-6  lines
1
1
0
0
-8  lines
1
1
0
1
-10 lines
1
1
1
0
-12 lines
1
1
1
1
-14 lines
Bit No.
Setting 
value
5
6
7
8
Page of 73
Display