MX-FX10 SIMULATIONS, FAX SOFTWARE SWITCH 4-50
120 1-4 Scan effective 
image area (SPF) 
back surface, Sub 
scanning, Lead 
edge image loss
Binary input
Setting range: -56 - +56dots  1step = 8 dots
For Bit No., refer to the table of SW114.
0 line
5-8 Scan effective 
image area (SPF) 
back surface, Sub 
scanning, Rear 
edge image loss
Binary input
Setting range: -56 - +56 dots  1step = 8dots
For Bit No., refer to the table of SW114.
0 line
121 1-4 Scan effective 
image area (SPF) 
back surface, Main 
scanning, Left 
image loss
Binary input
Setting range: -56 - +56dots  1step = 8dots
For Bit No., refer to the table of SW114.
 
(However, the unit of a set value is dots.)
0 dot
5-8 Scan effective 
image area (SPF) 
back surface, Main 
scanning, Right 
edge image loss
Binary input
Setting range: -56 - +56dots  1step = 8dots
For Bit No., refer to the table of SW114.
 
(However, the unit of a set value is dots.)
0 dot
122 1-8 Scanning 
magnification ratio 
adjustment SPF 
(Main scanning)
Binary input
Setting range: -12.7% - +12.7%  1step = 0.1%
For Bit No., refer to the table of SW112.
0%
123 1-8 Scanning 
magnification ratio 
adjustment SPF 
(Sub scanning)
Binary input
Setting range: -12.7% - +12.7%  1step = 0.1%
For Bit No., refer to the table of SW112.
0%
124 1-8 Print magnification 
ratio adjustment, 
back surface (Main 
scanning)
Binary input
Setting range: -12.7% - +12.7%  1step = 0.1%
For Bit No., refer to the table of SW112.
0%
125 1-8 Print magnification 
ratio adjustment, 
back surface (Sub 
scanning)
Binary input
Setting range: -12.7% - +12.7%  1step = 0.1%
For Bit No., refer to the table of SW112.
0%
126 1-8 Scanning 
magnification ratio 
adjustment SPF, 
back surface (Main 
scanning)
Binary input
Setting range: -12.7% - +12.7%  1step = 0.1%
For Bit No., refer to the table of SW112.
0%
127 1-8 Scanning 
magnification ratio 
adjustment SPF, 
back surface (Sub 
scanning)
Binary input
Setting range: -12.7% - +12.7%  1step = 0.1% 
For Bit No., refer to the table of SW112.
0%
128 1,2 Ring sound quality
Calling sound ringing frequency setting
There are following four patterns:
Pattern 2
3-8 Not used
129 1-8 Not used
130 1-2 Non detection time 
out when receiving 
image
Binary input
60s
3-8 Not used
SW
No.
Bit 
No.
Item
Switch serection and function
Initial value
System 
settings
Bit No.
Setting value
1
2
0
0
Pattern 1 (1000Hz/926Hz)
0
1
Pattern 2 (1035Hz/956Hz)
1
0
Pattern 3 (1048Hz/967Hz)
1
1
Pattern 4 (1119Hz/1027Hz)
Bit No.
Setting 
value
1
2
0
0
60s
0
1
90s
1
0
120s
1
1
30s
Bit No.
Setting 
value
1
2
Page of 73
Display

Click on the first or last page to see other MX-FX10 service manuals if exist.