MX-FRX2U (serv.man3). 003-Firmware UPGRADE ... (1). - Sharp Copying Equipment Technical Bulletin (repair manual). Page 3

Read Sharp MX-FRX2U (serv.man3) Technical Bulletin online

Sharp Electronics (UK) Ltd., Technical Services Group
CCE-347
8
Counter information
from E-RIC
sometimes is not
notified correctly.
Problem that the invalid count value is notified only if the user whose count value is "20"
existed when counting "User information" from E-RIC has been corrected.
This issue is involved in only the Notification Processor of E-RIC, so there's no problem
on the count value on the main unit.
9
Addition of specifying
time for the
secondary transfer
cleaning.
(Support for SIM44-
28)
The timing of the secondary transfer cleaning has been changed from every 10 pages to
every 200 pages, and controlled not to show "Automatically adjusted" message.   Items
of P・ Q・ R have been added in SIM44-28, and it enables to change the threshold level
which judges the timing for the second transfer cleaning.
Default values are; "P : 200, Q : 300, R : 500", and Cleaning Time is 10 sec when pages
are more than 200, 22 sec when pages are more than P and less than 300, 33 sec when
pages are more than 500, and the cleaning is not conducted when pages are less than
200.
10
Support is provided
for MX-PEX1(EFI)
Support is provided for EFI controller MX-PEX1.  When installing MX-PEX1, the firmware
of this version has to be upgraded.
11
Stabilisation of the
image density when
copying multiple
pages
The problem was caused by the slight changes of the drum surface potential when
copying multiple pages.
Reduction of the density had no effect in practical use however modification has been
implemented to correct the developing bias, and stabilise the density depending on the
drum's running distance when copying multiple pages.
This feature will be operated automatically as the default after version upgrade of the
firmware.
12
Correction of 4mm
wide uneven colour
occurred every 95mm
pitch
In cold climate areas, if the sudden environmental changes occurs inside the machines
at chill of morning or by the heating condition afterward, the concentration difference is
generated between the exposed area of the drum when the drum stops and is on standby
and the sealed area for 4 mm wide, and this might cause the uneven colour or uneven
pitch.  Modification has been implemented to avoid to leave the drum stopping at the
same position, and to reduce the concentration difference by letting the drum idle for
2minutes after power ON the machine when the temperature is low, and rotate the drum
approximately 60 degrees (approx.0.2 sec) every 3 minutes while the machine is getting
ready afterward.  Please support individually only the users who are suffering from this
trouble with turning ON the Soft Switch of the engine.  (sim.55-1 : Set No.5 to 10000000)
13
Correction to enable
to find the server with
the Server Name
when Scan-To-SMB
Scan data might not be stored in the shared-folder on the server which was located
outside of the segment where MX series were placed.  If you do not specify the server
name but specify IP address directly as the destination of SMB sending, Scan data can
be saved correctly in the shared-folder on the specified server.  In addition, it has no
effect on the operations of existing Scan-To-E-mail, Scan-To-FTP and Scan-To-Desktop.
14
Correction of output
defect printing  in
MacOS9.2
environment OS9.2
caused by
MX2700FG (PS error)
When printing the data which has Bitmap image with binary format from Illustrator 10.0.3
in MacOS environment, PS error occasionally occurred during analysis of binary image
data.  Modification has been implemented to corrected to print out correctly without PS
error.
Page of 4