1
Correction of size
illegal jam
If the paper size is different from the size detected by the machine, it used to be handled
as the illegal jam.  Modification has been implemented not to handle it as the jam but to
output it as the invalid paper and display the message "Please check the paper size".
On the system with the options of Finisher Desk etc, it is necessary to upgrade the
version of firmware for those options at the same time.
(MX-FNX1/FNX2 : 010300, MX-DEX3/DEX4 : 0101J0)
2
Value of Colour
Balance Manual
Adjustment cannot be
reflected into User
Auto Calibration
On Colour Balance Manual Adjustment, modification has been implemented to reflect the
adjustment value after the manual adjustment and the value after conducting Half Tone
Density Correct Execution into User Auto Calibration.
Even before this change is implemented, there’s no problem for the users who adjust the
colour balance only with Auto.
3
Fax Reception
sometimes fails in
1W Energy Save
Mode
Under the conditions of "1W Energy Save Mode", "Auto Switch of TEL/FAX: ON",
"Number of Auto Reception Call: less than twice", and "External Telephone
Setting/Connecting Optional Receiver: ON", when recovering from Energy Save Mode
after Fax reception, there were some cases where Fax reception could not be done due
to the time-out from FAXBOX side.
Some areas where possibly takes time for processing on the firmware of the main unit
has been corrected, and the setting of time-out to receive the notification of
"Communication Start" has been changed from 10secs to 33secs on the firmware of
FAXBOX side.
4
Change of the default
value of the
Softswitch (SSW31-
5)
In Transaction Report for PC-FAX, the default value of the softswitch (SSW31-5) for the
setting whether to print the sent image into Transaction Report has been changed from
"0:No Print" to "1:Print".
5
Correction of problem
that the blank page is
outputted when
copy/Fax/print job is
taken place
(MX-4500/4501 only)
In order to allocate the margin against the rotating defect of the drum and belt motor, the
control of acceleration/deceleration of the drum motor has been modified.
Modification has been implemented to stop the job as PPD2_N1 jam, and not to output
the blank page when the rotating defect of the drum motor occurs during printing, and at
this time only F2 error will be displayed, and the history will be recorded as  "F2-50" or
"F2-51" in SIM22-4.
6
Change of the default
value of SIM43-1
For the countermeasure to improve the jam in the fusing unit, ACDFGJ value of SIM43-1
was set to "Current Default Value: -10
" at the point of production, but this time, the
default value itself has been changed to "Current Default Value: -10
".
Since some of the users might change this setting, it won't be changed by this version
upgrade however this value will be changed back to the default by resetting the
destination.
7
Change of the timing
when the process
control is conducted.
Modification has been implemented not to operate the process control until the job end or
until the point when ageing of 100 pages is completed.  As for the jobs less than 100
pages, the messages "Print quality is being automatically adjusted" or "Automatically
adjusted" will be no longer displayed by this modification.
If it requires long time for RIP processing of print data when printing, process control may
operate, and "Print quality is being automatically adjusted" or "Automatically adjusted"
may be displayed.
Page of 4
Display

Click on the first or last page to see other MX-FRX2U (serv.man3) service manuals if exist.