Read Sharp MX-FNX5 Service Manual online
MX-FNX5 REPLACEMENT AND ADJUSTMENT 3 – 4
[B] Exit guide HP sensor (
x 1, Pawls x3).
C. UPPER TRAY FULL AND EXIT SENSORS
(1) Upper Tray Full Sensor
1)
Remove the top cover.
2)
Remove the sensor cover [A] ( x 2).
3)
Remove the sensor bracket [B] ( x 1).
4)
Replace the upper tray full sensor [C] (
x1, x 1).
(2) Upper Tray Exit Sensor
1)
Remove the sensor bracket [D] ( x 1).
2)
Replace the upper tray exit sensor [E] (
x 1, x 1).
D. SHIFT TRAY EXIT SENSOR
• Remove the top cover (
1. COVERS -D.)
Remove:
[A] Sensor bracket ( x1)
[A] Sensor bracket ( x1)
[B] Shift tray exit sensor 1 ( x1,
x1)
[C] Shift tray exit sensor 2 ( x1,
x1)
[B]
[A]
[B]
[C]
[D]
[E]
[A]
[B]
[C]
Click on the first or last page to see other MX-FNX5 service manuals if exist.