Read Sharp MX-FN26 Service Manual online
MX-FN26 N TROUBLE CODE 5 – 2
F1-19
Finisher paper alignment motor F
trouble
trouble
F1-20
Finisher paper alignment motor R
trouble
trouble
F1-29
Finisher cooling fan trouble
F1-37
Finisher RAM data trouble
F1-50
Finisher incompatible trouble
Phenomenon
Operation trouble of the paper alignment plate F
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness of the motor
and the harness of the motor
Check &
Remedy
Remedy
Check the connection of the connector and the
harness in the motor line with the finisher control
PWB.
Connect the connector properly. Replace the
harness.
harness in the motor line with the finisher control
PWB.
Connect the connector properly. Replace the
harness.
Case 2
Cause
Paper alignment plate home position sensor F
(FAPHPS-F) trouble.
(FAPHPS-F) trouble.
Check &
Remedy
Remedy
Check to confirm that the FAPHPS-F turns ON/OFF
with SIM3-2.
If it does not turn ON/OFF, check the connection of
the connector and the harness of the sensor.
Replace the sensor.
with SIM3-2.
If it does not turn ON/OFF, check the connection of
the connector and the harness of the sensor.
Replace the sensor.
Case 3
Cause
Motor lock, an over current to the motor, intrusion of
foreign material.
foreign material.
Check &
Remedy
Remedy
Select the FPAM-F with SIM3-3 to check the
operation of the single unit.
Check to confirm that there is no foreign material in
the drive section and the alignment plate.
operation of the single unit.
Check to confirm that there is no foreign material in
the drive section and the alignment plate.
Case 4
Cause
Finisher control PWB trouble. Motor trouble
Check &
Remedy
Remedy
Replace the finisher control PWB or the motor.
Phenomenon
Operation trouble of the paper alignment plate R
Case 1
Cause
Connection trouble or disconnection of the connector
and the harness of the motor
and the harness of the motor
Check &
Remedy
Remedy
Check the connection of the connector and the
harness in the motor line with the finisher control
PWB.
Connect the connector properly. Replace the
harness.
harness in the motor line with the finisher control
PWB.
Connect the connector properly. Replace the
harness.
Case 2
Cause
Paper alignment plate home position sensor R
(FAPHPS-R) trouble.
(FAPHPS-R) trouble.
Check &
Remedy
Remedy
Check to confirm that the FAPHPS-R turns ON/OFF
with SIM3-2.
If it does not turn ON/OFF, check the connection of
the connector and the harness of the sensor.
Replace the sensor.
with SIM3-2.
If it does not turn ON/OFF, check the connection of
the connector and the harness of the sensor.
Replace the sensor.
Case 3
Cause
Motor lock, an over current to the motor, intrusion of
foreign material.
foreign material.
Check &
Remedy
Remedy
Select the FPAM-R with SIM3-3 to check the
operation of the single unit.
Check to confirm that there is no foreign material in
the drive section and the alignment plate.
operation of the single unit.
Check to confirm that there is no foreign material in
the drive section and the alignment plate.
Case 4
Cause
Finisher control PWB trouble. Motor trouble
Check &
Remedy
Remedy
Replace the finisher control PWB or the motor.
Phenomenon
When the finisher cooling fan is operating, the lock
signal is not canceled in a certain time.
signal is not canceled in a certain time.
Case 1
Cause
Improper connection or disconnection of the fan
connector and harness.
connector and harness.
Check &
Remedy
Remedy
Check the connector and harness of the finisher
control PWB and the fan line.
Connect the connector securely. Replace the
harness.
control PWB and the fan line.
Connect the connector securely. Replace the
harness.
Case 2
Cause
Motor lock, an over current to the motor, intrusion of
a foreign material.
a foreign material.
Check &
Remedy
Remedy
Select the FCF with SIM03-03 and check the
operation of the single unit.
operation of the single unit.
Case 3
Cause
Finisher control PWB trouble, fan trouble.
Check &
Remedy
Remedy
Replace the finisher control PWB or the fan.
Phenomenon
Backup RAM operation trouble
Case 1
Cause
Finisher control PWB trouble. EEPROM trouble.
Check &
Remedy
Remedy
Replace the finisher control PWB or the EEPROM.
Phenomenon
Connection of a finisher incompatible with the
machine is detected.
machine is detected.
Case 1
Cause
Connection of a finisher incompatible with the
machine is detected.
machine is detected.
Check &
Remedy
Remedy
Connect the MX-FN26 to the machine.
Click on the first or last page to see other MX-FN26 service manuals if exist.