MX-C250, MX-C250E, MX-C250F, MX-C250FE, MX-C250FR, MX-C300F, MX-C300W, MX-C300WE, MX-C300A, MX-C300WR (serv.man6). Service Manual (Revised May 2016). - Sharp Copying Equipment Service Manual (repair manual). Page 111

Read Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual online

MX-C250  SIMULATION  6 – 33
44-9
Purpose
:
Operation data display
Function (Purpose)
: Used to display the results data of the high
density process control operation.
Section
:
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
Content description
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY 
RANGE
DEFAU
LT
VALUE
PROCON
DATA
1/12
P DV K
High density pro-
cess control DV 
data
0 - 600
450
P DV C
 (KCMY)
P DV M
P DV Y
2/12
P GB K
High density pro-
cess control GB 
data
150 - 850
610
P GB C
 (KCMY)
P GB M
P GB Y
3/12
P DV K 
BASE
High density pro-
cess control DV 
data
0 - 600
450
P DV C 
BASE
(KCMY) Target 
P DV M 
BASE
P DV Y 
BASE
4/12
P GB K 
BASE
High density pro-
cess control GB 
data
150 - 850
630
P GB C 
BASE
(KCMY) Target
P GB M 
BASE
P GB Y 
BASE
5/12
N(M)
DV K
High density pro-
cess control nor-
mal (medium speed 
) DV data
0 - 600
450
N(M)
DV C
(KCMY)
N(M)
DV M
N(M)
DV Y 
Result display
Content description
PROCON
DATA
6/12
N(M) 
GB K
High density pro-
cess control nor-
mal (medium speed 
) GB data
150 - 850
630
N(M) 
GB C
(KCMY)
N(M) 
GB M
N(M) 
GB Y
7/12
N(M) 
DV K 
BASE
High density pro-
cess control nor-
mal (medium speed 
) DV data
0 - 600
450
N(M) 
DV C 
BASE
(KCMY) Target
N(M) 
DV M 
BASE
N(M) 
DV Y 
BASE
8/12
N(M) 
GB K 
BASE
High density pro-
cess control nor-
mal (medium speed 
) GB data
150 - 850
630
N(M) 
GB C 
BASE
(KCMY) Target
N(M) 
GB M 
BASE
N(M) 
GB Y 
BASE
9/12
N(L) DV 
K
High density pro-
cess control nor-
mal(low speed ) DV 
data
0 - 600
450
N(L) DV 
C
(KCMY)
430
N(L) DV 
M
N(L) DV 
Y
10/12
N(L) GB 
K
High density pro-
cess control nor-
mal(low speed ) DV 
data
150 - 850
615
N(L) GB 
C
(KCMY) 
595
N(L) GB 
M
N(L) GB 
Y
11/12
N(L) DV 
K BASE
High density pro-
cess control nor-
mal(low speed ) DV 
data
0 - 600
450
N(L) DV 
C BASE
(KCMY) Target
430
N(L) DV 
M BASE
N(L) DV 
Y BASE
12/12
N(L) GB 
K BASE
High density pro-
cess control nor-
mal(low speed ) GB 
data
150- 850
615
N(L) GB 
C BASE
(KCMY) Target
595
N(L) GB 
M BASE
N(L) GB 
Y BASE
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY 
RANGE
DEFAU
LT
VALUE
Page of 127
Display