Read Sharp MX-C250 / MX-C250E / MX-C250F / MX-C250FE / MX-C250FR / MX-C300F / MX-C300W / MX-C300WE / MX-C300A / MX-C300WR (serv.man6) Service Manual online
MX-C250 SIMULATION 6 – 33
44-9
Purpose
:
Operation data display
Function (Purpose)
: Used to display the results data of the high
density process control operation.
Section
:
Image process (Photoconductor/Develop-
ing/Transfer/Cleaning)
ing/Transfer/Cleaning)
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key.
The set value in step 2) is saved.
ERROR
Abnormal end
INTERRUPTION
Forcible interruption
Details of error display
Content description
CL_SEN_ADJ_ERR
Color sensor adjustment abnormality
BK_SEN_ADJ_ERR
Black sensor adjustment abnormality
K_HV_ERR
K high density process control abnormality
C_HV_ERR
C high density process control abnormality
M_HV_ERR
M high density process control abnormality
Y_HV _ERR
Y high density process control abnormality
TIMEOUT_ERR
Time out
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY
RANGE
DEFAU
LT
VALUE
PROCON
DATA
DATA
1/12
P DV K
High density pro-
cess control DV
data
cess control DV
data
0 - 600
450
P DV C
(KCMY)
P DV M
P DV Y
P DV Y
2/12
P GB K
High density pro-
cess control GB
data
cess control GB
data
150 - 850
610
P GB C
(KCMY)
P GB M
P GB Y
P GB Y
3/12
P DV K
BASE
BASE
High density pro-
cess control DV
data
cess control DV
data
0 - 600
450
P DV C
BASE
BASE
(KCMY) Target
P DV M
BASE
P DV Y
BASE
BASE
P DV Y
BASE
4/12
P GB K
BASE
BASE
High density pro-
cess control GB
data
cess control GB
data
150 - 850
630
P GB C
BASE
BASE
(KCMY) Target
P GB M
BASE
P GB Y
BASE
BASE
P GB Y
BASE
5/12
N(M)
DV K
DV K
High density pro-
cess control nor-
mal (medium speed
) DV data
cess control nor-
mal (medium speed
) DV data
0 - 600
450
N(M)
DV C
DV C
(KCMY)
N(M)
DV M
N(M)
DV Y
DV M
N(M)
DV Y
Result display
Content description
PROCON
DATA
DATA
6/12
N(M)
GB K
GB K
High density pro-
cess control nor-
mal (medium speed
) GB data
cess control nor-
mal (medium speed
) GB data
150 - 850
630
N(M)
GB C
GB C
(KCMY)
N(M)
GB M
N(M)
GB Y
GB M
N(M)
GB Y
7/12
N(M)
DV K
BASE
DV K
BASE
High density pro-
cess control nor-
mal (medium speed
) DV data
cess control nor-
mal (medium speed
) DV data
0 - 600
450
N(M)
DV C
BASE
DV C
BASE
(KCMY) Target
N(M)
DV M
BASE
N(M)
DV Y
BASE
DV M
BASE
N(M)
DV Y
BASE
8/12
N(M)
GB K
BASE
GB K
BASE
High density pro-
cess control nor-
mal (medium speed
) GB data
cess control nor-
mal (medium speed
) GB data
150 - 850
630
N(M)
GB C
BASE
GB C
BASE
(KCMY) Target
N(M)
GB M
BASE
N(M)
GB Y
BASE
GB M
BASE
N(M)
GB Y
BASE
9/12
N(L) DV
K
K
High density pro-
cess control nor-
mal(low speed ) DV
data
cess control nor-
mal(low speed ) DV
data
0 - 600
450
N(L) DV
C
C
(KCMY)
430
N(L) DV
M
N(L) DV
Y
M
N(L) DV
Y
10/12
N(L) GB
K
K
High density pro-
cess control nor-
mal(low speed ) DV
data
cess control nor-
mal(low speed ) DV
data
150 - 850
615
N(L) GB
C
C
(KCMY)
595
N(L) GB
M
N(L) GB
Y
M
N(L) GB
Y
11/12
N(L) DV
K BASE
K BASE
High density pro-
cess control nor-
mal(low speed ) DV
data
cess control nor-
mal(low speed ) DV
data
0 - 600
450
N(L) DV
C BASE
C BASE
(KCMY) Target
430
N(L) DV
M BASE
N(L) DV
Y BASE
M BASE
N(L) DV
Y BASE
12/12
N(L) GB
K BASE
K BASE
High density pro-
cess control nor-
mal(low speed ) GB
data
cess control nor-
mal(low speed ) GB
data
150- 850
615
N(L) GB
C BASE
C BASE
(KCMY) Target
595
N(L) GB
M BASE
N(L) GB
Y BASE
M BASE
N(L) GB
Y BASE
MODE
PAGE
ITEM
CONTETNT
DIS-
PLAY
RANGE
DEFAU
LT
VALUE