MX-C250  SIMULATION  6 – 32
44-4
Purpose
:
Setting
Function (Purpose)
Used to set the conditions of the high den-
sity process control operation.
Section
Process
Operation/Procedure
1) Select an item to be set with Arrow keys.
2) Enter the set value with 10 keys.
3) Press [OK]/[START] key. 
The set value in step 2) is saved.
NOTE:
Set the items to the default values unless a change is spe-
cially required.
<*1 Reference value tables>
44-6
Purpose
:
Adjustment
Function (Purpose)
Used to execute the high density process
control forcibly.
Section
Process
Operation/Procedure
When [OK]/[START] key is pressed, the adjustment is exe-
cuted automatically.
After completion of the adjustment, the adjustment result is
displayed. (Refer to the table below.)
If the adjustment is not executed normally, "ERROR" is dis-
played.
REG_R_LED_ADJ
Registration sensor R adjustment abnor-
mality
REG_F_GRND
F registration basis material reading 
abnormality
REG_R_GRND
R registration basis material reading 
abnormality
Item/Display
Content
Setting 
range
Default 
value
1
PCS TARGET
Sensor target set value
1 - 255
204
2
PCS  ADJ  LIM
Sensor adjustment target limit 
value
1 - 255
8
3
BELT  G  DIF
Effective difference between the 
belt circuit substrate upper and 
lower limit values
1 - 255
1
4
B_BK STD DIF
Bias (for black) Target calcula-
tion difference
0 - 255
0
5
B PAT INT
Patch bias output interval
1 - 255
60
6
Y  TAR  ID
Patch density standard value 
(yellow)
1 - 255
*1
7
M TAR ID
Patch density standard value 
(magenta)
1 - 255
*1
8
C TAR ID
Patch density standard value 
(cyan)
1 - 255
*1
9
K  TAR  ID
Patch density standard value 
(black)
1 - 255
*1
10
HV BK_GR LIM
Patch position substrate light 
receiving effective range value
1 - 255
60
11
LED ADJ 
ROUGH
LED radiation quantity adjust-
ment rough 1step
1 - 255
5
12
LED ADJ 
ROUGH 
UPPER
LED radiation quantity adjust-
ment rough 1step execution  
threshold level  upper
1 - 255
240
13
LED ADJ 
ROUGH 
LOWER
LED radiation quantity adjust-
ment rough 1step execution  
threshold level  lower
1 - 255
140
14
K_PAT TARGET 
UPPER 1
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 1 (K-patch) 
1 - 255
10
15
K_PAT TARGET 
LOWER 1
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 1 (K-patch)
1 - 255
10
16
K_PAT TARGET 
UPPER 2
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 2 (K-patch) 
1 - 255
15
17
K_PAT TARGET 
LOWER 2
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 2 (K-patch)
1 - 255
15
18
K_HT TARGET 
UPPER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 1 (K-patch) 
1 - 255
10
19
K_HT TARGET 
LOWER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 1 (K-patch)
1 - 255
10
Error name
Error content
20
K_HT TARGET 
UPPER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 2 (K-patch) 
1 - 255
15
21
K_HT TARGET 
LOWER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 2 (K-patch)
1 - 255
15
22
CL_PAT TAR-
GET UPPER 1
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 1 (CL-patch) 
1 - 255
10
23
CL_PAT TAR-
GET LOWER 1
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 1 (CL-patch)
1 - 255
10
24
CL_PAT TAR-
GET UPPER 2
Simplified process control solid-
patch transition judgment to high 
density process control upper 
limitation 2 (CL-patch) 
1 - 255
15
25
CL_PAT TAR-
GET LOWER 2
Simplified process control solid-
patch transition judgment to high 
density process control lower 
limitation 2 (CL-patch)
1 - 255
15
26
CL_HT TAR-
GET UPPER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 1 (CL-patch) 
1 - 255
10
27
CL_HT TAR-
GET LOWER 1
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 1 (CL-patch)
1 - 255
10
28
CL_HT TAR-
GET UPPER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
upper limitation 2 (CL-patch) 
1 - 255
15
29
CL_HT TAR-
GET LOWER 2
Simplified process control half-
tone-patch transition judgment 
to high density process control 
lower limitation 2 (CL-patch)
1 - 255
15
30
SP_PAT COEF 
UPP DIF
Simplified process control den-
sity coefficient upper threshold 
level
1 - 255
10
31
SP_PAT COEF 
LOW DIF
Simplified process control den-
sity coefficient lower threshold 
level
1 - 255
10
No.
Item/Display
Default value for each Group
Group A
Group B
Group C
6
Y TAR ID
48
48
48
7 M 
TAR 
ID
50
50
50
8
C TAR ID
50
50
50
9
K TAR ID
48
50
48
Group
Destination
Group A
Japan
-
-
-
-
-
Group B
U.S.A.
Canada
Inch
-
-
-
Group C
Europe
U.K.
AUS
AB_A
China
AB_B
Result display
Content description
COMPLETE
Normal complete
Item/Display
Content
Setting 
range
Default
value
4
‘14/Apr
4
4
Page of 127