MX-6500N, MX-7500N (serv.man10). Installation Manual (Revised May 2017). - Sharp Copying Equipment Service Manual (repair manual). Page 13

Read Sharp MX-6500N / MX-7500N (serv.man10) Service Manual online

MX-7500N  MX-7500N/6500N (MAIN UNIT)  2 – 3
(2)
Scanner (2/3 mirror unit) lock release
1)
Remove the optical unit fixing screw, and remove the note
label.
C. Attach the operation panel
1)
Install the Panel arm (Packed item No.3) by fixing the screws
(2: Packed item No.16, 3: Packed item No.14).
2)
Put the Arm cover A (Packed item No.4) temporarily as the fig-
ure below.
3)
Install the Panel (Packed item No.5) by fixing the screws
(Packed item No.14).
4)
Arrange the wire and fix the screw as the figure below.
NOTE: Handle the connectors with care not to make damage
to the connector when connecting.
NOTE: Connect the connectors vertically to the PWB.
NOTE: When arranging the cable, never twist it.
NOTE: Handle the connectors with care not to make damage
to the connector by snagging them when wiring.
5)
Install the Arm cover B (Packed item No.6) by fixing the screws
(Packed item No.14).