MX-6240N, MX-7040N (serv.man26). Section 7 Troubleshooting - Updated November 2012 - Sharp Copying Equipment Service Manual (repair manual). Page 43

Read Sharp MX-6240N / MX-7040N (serv.man26) Service Manual online

MX-7040N  TROUBLESHOOTING  7 – 43
 
L4-48
ADU  transport co oling  fan motor F
trouble
 
L4-49
ADU  transport cooling fan motor R
trouble
 
L4-57
Toner bottle cooling fan motor trouble
 
L4-60
Fusing  pressure roller co oling  fan
motor F trouble
 
L4-61
Fusing  pressure roller cooling 
fan
motor R trouble
 
L6-10
Polygon motor trouble
 
L8-01
Full wave signal detection error
 
L8-02
Full wave signal error
Trouble content
The lock signal is detected during rotation of the ADU 
transport cooling fan motor F.
Detail
PCU
Cause
Harness/connector trouble between the PCU PWB 
and the fan motor.
PCU PWB trouble.
Fan motor trouble.
The fan does not rotate because of the other trouble. 
(No power supply to the fan motor) 
Check & Remedy
Use SIM6-2 to check the operation of the fan motor.
Check the harness and the connector between the 
PCU PWB and the fan motor.
Replace the PCU PWB.
Replace the fan motor.
Trouble content
The lock signal is detected during rotation of the ADU 
transport cooling fan motor R.
Detail
PCU
Cause
Harness/connector trouble between the PCU PWB 
and the fan motor.
PCU PWB trouble.
Fan motor trouble.
The fan does not rotate because of the other trouble. 
(No power supply to the fan motor) 
Check & Remedy
Use SIM6-2 to check the operation of the fan motor.
Check the harness and the connector between the 
PCU PWB and the fan motor.
Replace the PCU PWB.
Replace the fan motor.
Trouble content
The fan operation signal is not detected within the 
specified time in the toner bottle cooling fan 
operation.
Detail
PCU
Cause
The fan does not rotate because of disconnection of 
the fan connector or other trouble.
Check & Remedy
Check the harness and the connector between the 
PCU PWB and the fan motor.
Check that the fan is rotating after turning ON the 
power.
Trouble content
When the fan is operated, the fan operation signal is 
not detected within the specified time.
Detail
PCU
Cause
Harness connection trouble between the PCU PWB 
and the fan motor.
PCU PWB trouble.
Fan motor trouble.
The fan does not rotate because of the other trouble. 
(No power supply to the fan motor)
Check & Remedy
Use SIM6-2 to check the operation of the fan motor.
Check the harness and the connector between the 
PCU PWB and the fan motor.
Replace the PCU PWB.
Replace the fan motor.
Trouble content
When the fan is operated, the fan operation signal is 
not detected within the specified time.
Detail
PCU
Cause
Harness connection trouble between the PCU PWB 
and the fan motor.
PCU PWB trouble.
Fan motor trouble.
The fan does not rotate because of the other trouble. 
(No power supply to the fan motor)
Check & Remedy
Use SIM6-2 to check the operation of the fan motor.
Check the harness and the connector between the 
PCU PWB and the fan motor.
Replace the PCU PWB.
Replace the fan motor.
Trouble content
The polygon motor does not reach the specified RPM 
within the specified time after starting rotation of the 
polygon motor.
Detail
PCU
Cause
Polygon motor trouble.
LSU control PWB trouble.
Connection trouble of the connector and the harness.
Check & Remedy
Use SIM61-1 to check the operation of the polygon 
motor.
Check connection of the connector and the harness.
Replace the LSU.
Replace the LSU control PWB.
Trouble content
The full wave signal is not detected.
Detail
PCU
Cause
PCU PWB trouble.
Power unit trouble.
Connection trouble of the connector and the harness.
Check & Remedy
Replace the PCU PWB.
Replace the power unit.
Check connection of the connector and the harness.
Trouble content
Detail
PCU
Cause
An abnormality in the full wave signal frequency is 
detected.
(The frequency is detected as 65Hz or above, or 
45Hz or less.)
PCU PWB trouble.
Power unit trouble.
Connection trouble of the connector and the 
harness.
Power frequency, waveform abnormality.
Check & Remedy
Replace the PCU PWB.
Replace the power unit.
Check connection of the connector and the harness.
Check the power waveform.
Page of 69
Display